Engineering, Management, Agriculture and Veterinary MCQs are now live. FPSC, PPSC, EPE, IELTS & GRE coming soon.

Hydraulics & Fluid Mechanics: Reaction Turbines (Francis and Kaplan)

Civil Engineering · Hydraulics & Fluid Mechanics

50 questions, each with the answer and a worked solution. Notes on units and constants are at the top.

Practice interactively and track your score →

Units and constants

SI units throughout. Take g = 9.81 m/s² and the density of water as 1000 kg/m³ wherever a value is needed.

Question 1

A Kaplan turbine is preferred for a specific speed range of:

  1. 10 to 50 r.p.m.
  2. 60 to 300 r.p.m.
  3. 300 to 1000 r.p.m.
  4. Above 1200 r.p.m.
Show answer & solution

Answer: (C) 300 to 1000 r.p.m.

Kaplan turbines are used for specific speeds of about 300 to 1000 r.p.m.

Question 2

The efficiency of a reaction turbine for a given head ……………. with increase in speed up to optimum point.

  1. Increases
  2. Decreases
  3. Remains unchanged
  4. Drops sharply
Show answer & solution

Answer: (A) Increases

For a given head, efficiency rises with speed to a maximum at the design (optimum) speed, then falls.

Question 3

In a reaction turbine, how does water enter and flow over the vanes?

  1. Enters under pressure and loses pressure progressively over the vanes
  2. Enters at atmospheric pressure as a free jet
  3. Enters with zero velocity
  4. Flows entirely by its gravitational weight
Show answer & solution

Answer: (A) Enters under pressure and loses pressure progressively over the vanes

In a reaction turbine water enters under pressure and the pressure falls progressively as it flows over the vanes.

Question 4

In an outward flow reaction turbine:

  1. Water enters at outer periphery and flows inward
  2. Flow is tangential
  3. Water enters at the centre and flows towards the outer periphery
  4. Flow is purely axial
Show answer & solution

Answer: (C) Water enters at the centre and flows towards the outer periphery

In an outward flow turbine water enters at the centre and flows radially outwards.

Question 5

According to the action of water on the runner, turbines are classified as

  1. high head and low head turbines
  2. vertical and horizontal turbines
  3. tangential and mixed-flow turbines
  4. impulse and reaction turbines
Show answer & solution

Answer: (D) impulse and reaction turbines

Impulse turbines use only jet kinetic energy at atmospheric pressure; reaction turbines use both pressure and kinetic energy.

Question 6

The discharge through a reaction turbine ……………. with increase in unit speed.

  1. Increases
  2. Remains same
  3. Drops to zero
  4. Decreases
Show answer & solution

Answer: (D) Decreases

On the unit-discharge vs unit-speed curve of a reaction turbine, unit discharge decreases as unit speed increases.

Question 7

The speed ratio of a Francis turbine is defined as the ratio of:

  1. Theoretical jet velocity to peripheral speed
  2. Discharge velocity to inlet velocity
  3. Flow velocity to runner speed
  4. Peripheral speed at inlet to theoretical jet velocity
Show answer & solution

Answer: (D) Peripheral speed at inlet to theoretical jet velocity

Speed ratio = peripheral speed at inlet / √(2gH) (theoretical jet velocity).

Question 8

The ratio of actual work available at the turbine shaft to the energy imparted to the wheel runner is known as …………… efficiency.

  1. Hydraulic
  2. Volumetric
  3. Mechanical
  4. Overall
Show answer & solution

Answer: (C) Mechanical

Shaft power / power imparted to the runner is the mechanical efficiency.

Question 9

In a Francis turbine, the pressure at inlet is …………. that at outlet.

  1. Less than
  2. Equal to
  3. More than
  4. Independent of
Show answer & solution

Answer: (C) More than

Water enters a Francis turbine under pressure and leaves at lower pressure, so inlet pressure is higher than outlet pressure.

Question 10

In an axial flow reaction turbine, water flows …………. to the axis of the wheel.

  1. Parallel
  2. Perpendicular
  3. At 45 degrees
  4. Radially outward
Show answer & solution

Answer: (A) Parallel

In an axial flow turbine water flows parallel to the axis of the wheel.

Question 11

The discharge through a turbine is proportional to:

  1. H^(1/2)
  2. H^(3/2)
  3. H²
  4. H
Show answer & solution

Answer: (A) H^(1/2)

Q = C_d·A·√(2gH), so Q ∝ √H.

Question 12

The overall efficiency of a turbine is the product of the

  1. hydraulic and mechanical efficiencies
  2. hydraulic efficiency and the speed ratio
  3. mechanical efficiency and the jet ratio
  4. volumetric efficiency and the flow ratio
Show answer & solution

Answer: (A) hydraulic and mechanical efficiencies

Overall efficiency = hydraulic × mechanical (and volumetric where leakage matters), accounting for all losses between water power and shaft power.

Question 13

The permissible setting height of a Francis runner above the tailrace is assessed using the

  1. speed ratio of the runner
  2. Thoma's cavitation factor
  3. Reynolds number of the draft tube flow
  4. Froude number at the tailrace
Show answer & solution

Answer: (B) Thoma's cavitation factor

Thoma's sigma compares the available net positive suction head with the net head and gives the safe setting.

Question 14

The speed ratio in the case of a Francis turbine varies from:

  1. 0.15 to 0.3
  2. 0.6 to 0.9
  3. 1.0 to 1.2
  4. 1.5 to 2.0
Show answer & solution

Answer: (B) 0.6 to 0.9

Speed ratio for Francis turbines is typically 0.6 to 0.9.

Question 15

In a reaction turbine, water enters the runner with

  1. kinetic energy alone, at atmospheric pressure
  2. pressure energy alone, with negligible velocity
  3. kinetic energy alone, at rising pressure
  4. pressure and kinetic energy, with pressure falling
Show answer & solution

Answer: (D) pressure and kinetic energy, with pressure falling

Water arrives under pressure with velocity, and its pressure drops as it moves through the runner passages doing work.

Question 16

The risk of cavitation in a Francis turbine increases when the runner is set

  1. lower, below the tailrace level
  2. higher above the tailrace level
  3. at a lower specific speed
  4. with a higher tailrace water level
Show answer & solution

Answer: (B) higher above the tailrace level

A higher setting lowers the pressure at the runner exit toward vapour pressure, causing cavitation.

Question 17

As the specific speed of a Francis runner increases, the runner becomes

  1. unchanged in shape but larger in diameter
  2. wider, with flow becoming more axial
  3. wider, with flow becoming purely radial
  4. narrower, with flow becoming more radial
Show answer & solution

Answer: (B) wider, with flow becoming more axial

Higher specific speed corresponds to lower head and larger discharge, so the runner widens and tends towards axial flow.

Question 18

At constant discharge, the power produced by a reaction turbine is ______ to the net head H.

  1. Proportional to H^(3/2)
  2. Independent of head
  3. Directly proportional
  4. Inversely proportional
Show answer & solution

Answer: (C) Directly proportional

P = wQHη, so at constant discharge power is directly proportional to H.

Question 19

The runner blades of a conventional Francis turbine are

  1. adjustable by a servomotor, as in the Kaplan
  2. hinged to turn during part-load operation
  3. fixed to the hub and not adjustable
  4. replaced by flexible vanes at part load
Show answer & solution

Answer: (C) fixed to the hub and not adjustable

Francis runner blades are fixed; flow is regulated only by the guide vanes.

Question 20

A Francis turbine is typically used when the available head of water is within:

  1. 0 to 25 m
  2. 25 m to 250 m
  3. Above 250 m
  4. Above 1000 m
Show answer & solution

Answer: (B) 25 m to 250 m

Francis turbines are used for medium heads of about 25 m to 250 m.

Question 21

According to the head available, turbines are classified as

  1. high head, medium head and low head turbines
  2. axial, radial and mixed-flow turbines
  3. impulse and reaction turbines
  4. tangential and outward-flow turbines
Show answer & solution

Answer: (A) high head, medium head and low head turbines

Turbines are grouped by operating head into high (Pelton), medium (Francis) and low (Kaplan) head types.

Question 22

In a mixed flow reaction turbine, the flow of water is:

  1. Purely gravitational
  2. Partly radial and partly axial
  3. Purely tangential
  4. Purely radial inward
Show answer & solution

Answer: (B) Partly radial and partly axial

In a mixed flow turbine water enters radially and leaves axially, so the flow is partly radial and partly axial.

Question 23

The flow ratio in the case of a Francis turbine typically varies from:

  1. 0.15 to 0.3
  2. 0.4 to 0.5
  3. 0.6 to 0.9
  4. 1.0 to 1.5
Show answer & solution

Answer: (A) 0.15 to 0.3

For Francis turbines the flow ratio typically lies between 0.15 and 0.3.

Question 24

In a mixed-flow reaction turbine such as the modern Francis turbine, water enters

  1. radially and leaves radially
  2. radially and leaves axially
  3. axially and leaves axially
  4. axially and leaves radially
Show answer & solution

Answer: (B) radially and leaves axially

Radial entry and axial exit give the flow both radial and axial components.

Question 25

The degree of reaction of a turbine is the ratio of

  1. shaft power to the power available in the water
  2. pressure energy change to total energy change in runner
  3. kinetic energy change to total energy change in runner
  4. pressure head at runner inlet to the net head
Show answer & solution

Answer: (B) pressure energy change to total energy change in runner

R = (change in static pressure head across the runner) / (total head change across the runner).

Question 26

Which of the following measures helps to avoid cavitation in a reaction turbine to a great extent?

  1. Installing the turbine below tailrace level
  2. Installing the turbine high above tailrace level
  3. Running the runner far above its design speed
  4. Operating the turbine at heads well below the rated head
Show answer & solution

Answer: (A) Installing the turbine below tailrace level

Setting the turbine runner below the tailrace level keeps pressure at the runner exit above vapour pressure, which suppresses cavitation.

Question 27

The ratio of runner width to diameter at inlet of a Francis turbine is called the

  1. jet ratio
  2. flow ratio
  3. width ratio
  4. speed ratio
Show answer & solution

Answer: (C) width ratio

Width ratio n = B1/D1 characterises runner shape.

Question 28

In an axial-flow reaction turbine such as the Kaplan, water flows

  1. parallel to the shaft axis through the runner
  2. tangentially around the shaft only
  3. radially outward from the hub
  4. radially inward through the runner
Show answer & solution

Answer: (A) parallel to the shaft axis through the runner

The flow stays parallel to the rotational axis throughout the runner.

Question 29

At very low heads, compared with a Francis turbine, a Kaplan turbine generally offers

  1. lower efficiency, since its runner passes too little flow
  2. higher efficiency, being designed for low head and large flow
  3. similar efficiency, since both have the same specific speed
  4. lower efficiency, since it cannot regulate flow at part load
Show answer & solution

Answer: (B) higher efficiency, being designed for low head and large flow

Kaplan runners are optimised for low head and large discharge, so they outperform Francis runners in that range.

Question 30

In a Kaplan turbine runner, the number of blades is generally between:

  1. 2 to 4
  2. 4 to 8
  3. 8 to 16
  4. 16 to 24
Show answer & solution

Answer: (B) 4 to 8

Kaplan runners generally have 4 to 8 blades.

Question 31

Which of the following statements about the guide vanes of a reaction turbine is correct?

  1. They guide the water onto the runner without shock and regulate the discharge
  2. They bring the runner to rest quickly by deflecting the jet
  3. They recover the kinetic energy of water leaving the runner
  4. They increase the pressure of water entering the casing
Show answer & solution

Answer: (A) They guide the water onto the runner without shock and regulate the discharge

Guide vanes direct the water onto the runner without shock and regulate the discharge into the turbine.

Question 32

The hydraulic efficiency of a reaction turbine is defined as the ratio of:

  1. Work done on the wheel to the energy actually supplied to the turbine
  2. Shaft power to water power
  3. Water power supplied to the work done on the wheel
  4. Shaft power developed to the work done on the wheel
Show answer & solution

Answer: (A) Work done on the wheel to the energy actually supplied to the turbine

Hydraulic efficiency = work done on the wheel / energy (head) actually supplied to the turbine.

Question 33

A Francis turbine is classified as:

  1. An outward flow reaction turbine
  2. An axial flow propeller turbine
  3. An impulse tangential turbine
  4. An inward or mixed flow reaction turbine
Show answer & solution

Answer: (D) An inward or mixed flow reaction turbine

Francis turbine is an inward flow (modern design mixed flow) reaction turbine.

Question 34

In a Francis turbine runner, the number of blades is generally between:

  1. 2 to 4
  2. 4 to 8
  3. 8 to 16
  4. 16 to 24
Show answer & solution

Answer: (D) 16 to 24

Francis runners generally have 16 to 24 blades.

Question 35

If all the energy change in the runner were due to pressure change, the degree of reaction would be

  1. 0
  2. 1
  3. 0.5
  4. 0.75
Show answer & solution

Answer: (B) 1

Degree of reaction is the pressure-energy fraction of the total energy change, which would be 1 in this case.

Question 36

The guide vanes of a Kaplan turbine are

  1. fixed, with only the runner blades adjustable
  2. absent, with flow set by runner blade angle
  3. adjustable and coordinated with runner blade angle
  4. locked after start-up and not moved again
Show answer & solution

Answer: (C) adjustable and coordinated with runner blade angle

Guide vane and blade angle are changed together through a cam, so flow enters shock-free at all loads.

Question 37

The Furneyron turbine is …………… reaction turbine.

  1. An inward flow
  2. A mixed flow
  3. An axial flow
  4. An outward flow
Show answer & solution

Answer: (D) An outward flow

Furneyron turbine is an outward flow reaction turbine.

Question 38

A propeller turbine differs from a Kaplan turbine in having

  1. a nozzle in place of the guide vanes
  2. adjustable runner blades with fixed guide vanes
  3. fixed runner blades with no pitch adjustment
  4. a radial rather than axial flow path
Show answer & solution

Answer: (C) fixed runner blades with no pitch adjustment

A propeller turbine is a Kaplan-type axial machine whose runner blades are fixed.

Question 39

Thomson’s turbine is …………. reaction turbine.

  1. A mixed flow
  2. An outward flow
  3. An axial flow
  4. An inward flow
Show answer & solution

Answer: (D) An inward flow

Thomson's (vortex) turbine is an inward flow reaction turbine.

Question 40

In a reaction turbine, the pressure head of water while flowing over the vanes is:

  1. Maintained constant throughout
  2. Completely lost to friction
  3. Converted partly into kinetic head before leaving the wheel
  4. Converted into heat energy
Show answer & solution

Answer: (C) Converted partly into kinetic head before leaving the wheel

In a reaction turbine part of the pressure head is converted to kinetic head while flowing through the runner.

Question 41

If a Francis turbine is run below 50 percent head for a long period:

  1. Discharge becomes constant
  2. It loses efficiency and cavitation danger becomes significantly more serious
  3. It operates at peak mechanical efficiency
  4. Cavitation is completely eliminated
Show answer & solution

Answer: (B) It loses efficiency and cavitation danger becomes significantly more serious

Running well below design head reduces efficiency and increases the risk of cavitation.

Question 42

The guide vanes of a Francis turbine are

  1. adjustable, to regulate flow and power
  2. fixed, with flow regulated by a spear
  3. fixed, and used only to straighten the flow
  4. fixed, with flow regulated by runner blade pitch
Show answer & solution

Answer: (A) adjustable, to regulate flow and power

Turning the wicket gates changes the flow area and entry angle, so the discharge and power are governed.

Question 43

The power developed by a turbine is proportional to:

  1. H^(1/2)
  2. H
  3. H^(3/2)
  4. H²
Show answer & solution

Answer: (C) H^(3/2)

P ∝ Q·H with Q ∝ √H, so P ∝ H^(3/2).

Question 44

In an inward flow reaction turbine:

  1. Flow is entirely axial
  2. Water enters at the centre and flows towards outer periphery
  3. Water flows parallel to the main shaft axis
  4. Water enters at the outer periphery and flows towards the centre
Show answer & solution

Answer: (D) Water enters at the outer periphery and flows towards the centre

In an inward flow turbine water enters at the outer periphery and flows radially inwards.

Question 45

The flow ratio of a Francis turbine is defined as the ratio of:

  1. Velocity of flow at inlet to theoretical jet velocity √(2gH)
  2. Theoretical jet velocity to velocity of flow
  3. Peripheral runner speed to flow velocity
  4. Velocity of flow at outlet to peripheral speed at inlet
Show answer & solution

Answer: (A) Velocity of flow at inlet to theoretical jet velocity √(2gH)

Flow ratio = V_f1/√(2gH).

Question 46

A turbine is a hydraulic machine that converts

  1. electrical energy into hydraulic energy
  2. hydraulic energy into mechanical energy
  3. mechanical energy into electrical energy
  4. mechanical energy into hydraulic energy
Show answer & solution

Answer: (B) hydraulic energy into mechanical energy

A turbine extracts energy from flowing water and delivers it as shaft work.

Question 47

The inlet blade angle of a Francis runner is designed so that water enters

  1. tangentially for any guide vane setting
  2. without shock at the design flow
  3. at maximum incidence to raise torque
  4. striking the blade face to maximise impact
Show answer & solution

Answer: (B) without shock at the design flow

Shock-free entry at design discharge minimises eddy losses at the best efficiency point.

Question 48

The gross or total head of a turbine is the …………… of the water levels at the head race and tail race.

  1. Ratio
  2. Difference
  3. Product
  4. Sum
Show answer & solution

Answer: (B) Difference

Gross head = head race level − tail race level (difference of the water levels).

Question 49

For a given head and efficiency, the power developed by a turbine is ______ the weight of water flowing per second.

  1. Inversely proportional to
  2. Directly proportional to
  3. Independent of
  4. Proportional to the square root of
Show answer & solution

Answer: (B) Directly proportional to

Power = (w Q H) η, so for given head and efficiency the work done is directly proportional to the weight of water flowing per second.

Question 50

The speed of a turbine runner under varying heads is proportional to:

  1. H^(3/2)
  2. H^(1/2)
  3. H
  4. H²
Show answer & solution

Answer: (B) H^(1/2)

Since peripheral speed u = φ√(2gH), N ∝ √H.

Practice these 50 questions interactively →