Le-chatelier method is used to determine
Show answer & solution
Answer: (C) soundness of cement
The Le-Chatelier apparatus detects unsoundness in cement caused by excessive free lime expansion.
Civil Engineering · Building Materials
20 questions, each with the answer and a worked solution.
Practice interactively and track your score →Le-chatelier method is used to determine
Answer: (C) soundness of cement
The Le-Chatelier apparatus detects unsoundness in cement caused by excessive free lime expansion.
Greater fineness of cement generally results in
Answer: (B) faster rate of hydration and higher early strength, though it may also increase the heat of hydration and shrinkage
Finer cement particles hydrate faster, boosting early strength, but at the cost of higher heat generation and shrinkage.
The compound in cement mainly responsible for later (long-term) strength gain is
Answer: (B) Dicalcium silicate (C2S)
C2S hydrates more slowly, contributing mainly to the continued strength gain beyond 28 days.
The compound responsible for the initial setting of cement is
Answer: (A) tri-calcium aluminate
Tri-calcium aluminate (C3A) hydrates very rapidly upon water addition, controlling the initial setting behavior of cement.
The compressive strength of cement is standard-tested using cement mortar cubes, typically checked at ages of
Answer: (B) 3 days, 7 days, and 28 days, as common standard testing ages
Standard cement testing checks compressive strength at 3, 7, and 28 days on mortar cubes.
The expansion of cement should not exceed _____________ for any type of Portland cement.
Answer: (B) 10 mm
Using the Le-Chatelier test, expansion caused by free lime in Portland cement must not exceed 10 mm.
The final setting time of ordinary Portland cement, as tested by the Vicat apparatus, should generally not exceed
Answer: (B) 10 hours (600 minutes)
Standard specifications cap the final setting time at around 10 hours (600 minutes).
The final setting time of ordinary cement should not be more than
Answer: (D) 10 hours
Standard specifications require ordinary Portland cement to achieve final set within 10 hours so hardening proceeds reliably.
The fineness of cement is commonly tested using
Answer: (A) a sieve analysis (such as the 90-micron sieve test) or a Blaine air permeability test
Fineness is standardly measured by sieve residue or the Blaine air permeability method.
The grade of ordinary Portland cement, such as 33, 43, or 53, indicates its
Answer: (B) minimum compressive strength (in N/mm2, or MPa) at 28 days, as tested on standard mortar cubes
The grade number directly states the minimum 28-day compressive strength guaranteed for that cement.
The initial setting time of ordinary Portland cement, as tested by the Vicat apparatus, should generally not be less than
Answer: (A) 30 minutes
Standard specifications require an initial setting time of at least 30 minutes.
The initial setting time of rapid hardening cement should not be less than
Answer: (A) 30 min
Like ordinary cement, rapid hardening cement must allow adequate working time, with initial setting time not less than 30 minutes.
The main chemical compound in cement responsible for early strength gain is
Answer: (A) Tricalcium silicate (C3S)
C3S hydrates relatively quickly, giving cement most of its early (up to about 28-day) strength.
The normal consistency of Portland cement is about
Answer: (D) 25%
Standard Vicat needle tests show normal consistency paste requirements clustering around 25% to 30% water by weight.
The normal consistency of a cement paste, determined using the Vicat apparatus, refers to the
Answer: (B) water content that gives the paste a standard, specified penetration/consistency, used as a basis for further setting time and soundness tests
Normal consistency defines the water content giving a standard paste stiffness, used as the basis for subsequent setting-time and soundness tests.
The soundness of cement, tested using the Le Chatelier apparatus (or autoclave test), is a measure of its
Answer: (A) tendency to undergo excessive, disruptive volume expansion after setting, mainly due to free (uncombined) lime, magnesia, or excess calcium sulfate
Soundness testing checks for expansive tendencies from unreacted free lime/magnesia that could crack hardened cement later.
The specific gravity of ordinary Portland cement is approximately
Answer: (B) 3.15
OPC has a typical specific gravity of about 3.15.
The specific surface (in cm²/g) of a good Portland cement should not be less than
Answer: (C) 2250
A good quality Portland cement must have a minimum specific surface area of 2250 cm²/g (225 m²/kg) as measured by Blaine permeability.
The ultimate strength of cement is provided by
Answer: (B) di-calcium silicate
Di-calcium silicate (C2S) hydrates slowly over months, contributing significantly to long-term ultimate strength and durability.
Tricalcium aluminate (C3A) in cement is associated mainly with
Answer: (B) rapid setting/hydration and relatively high heat of hydration, but contributing little to long-term strength
C3A reacts and hydrates very quickly, generating significant heat, but adds little to the cement's ultimate strength.