Engineering, Management, Agriculture and Veterinary MCQs are now live. FPSC, PPSC, EPE, IELTS & GRE coming soon.

Power Plant Engineering: Power Plant Economics

Mechanical Engineering · Power Plant Engineering

25 questions, each with the answer and a worked solution.

Practice interactively and track your score →
Question 1

What is a load curve?

  1. A graph of fuel cost
  2. A graph of efficiency
  3. A graph showing the variation of electrical load with time
  4. A graph of turbine speed
Show answer & solution

Answer: (C) A graph showing the variation of electrical load with time

The area under it gives the energy consumed.

Question 2

What is a load duration curve?

  1. A curve showing loads arranged in descending order of magnitude against the time for which they occur
  2. A curve of voltage
  3. A curve of fuel use
  4. A curve of load against time of day
Show answer & solution

Answer: (A) A curve showing loads arranged in descending order of magnitude against the time for which they occur

It helps select base and peak load plants.

Question 3

What is load factor?

  1. The ratio of energy to fuel
  2. The ratio of average load to maximum demand over a period
  3. The ratio of maximum demand to connected load
  4. The ratio of power to voltage
Show answer & solution

Answer: (B) The ratio of average load to maximum demand over a period

A high load factor reduces the cost per unit generated.

Question 4

What is demand factor?

  1. The ratio of energy to capacity
  2. The ratio of average load to maximum demand
  3. The ratio of maximum demand to connected load
  4. The ratio of sum of individual maximum demands to system maximum demand
Show answer & solution

Answer: (C) The ratio of maximum demand to connected load

It is usually less than 1.

Question 5

What is diversity factor?

  1. The ratio of the sum of individual maximum demands to the maximum demand of the whole system
  2. The ratio of average load to maximum demand
  3. The ratio of maximum demand to connected load
  4. The ratio of energy to fuel
Show answer & solution

Answer: (A) The ratio of the sum of individual maximum demands to the maximum demand of the whole system

It is greater than 1, because consumers do not all peak at once.

Question 6

What is plant capacity factor?

  1. The ratio of average load to maximum demand
  2. The ratio of fuel to energy
  3. The ratio of maximum demand to rated capacity
  4. The ratio of actual energy produced to the maximum energy that could be produced at rated capacity in the same period
Show answer & solution

Answer: (D) The ratio of actual energy produced to the maximum energy that could be produced at rated capacity in the same period

It shows how fully the plant is used.

Question 7

What is utilisation factor?

  1. The ratio of maximum demand on a plant to its rated capacity
  2. The ratio of energy to time
  3. The ratio of average load to maximum demand
  4. The ratio of connected load to demand
Show answer & solution

Answer: (A) The ratio of maximum demand on a plant to its rated capacity

It shows how much of the installed capacity is used at peak.

Question 8

A plant has a maximum demand of 100 MW and an average load of 60 MW. What is its load factor?

  1. 40%
  2. 60%
  3. 100%
  4. 166%
Show answer & solution

Answer: (B) 60%

Load factor = 60 ÷ 100.

Question 9

Which plants are usually used to supply base load?

  1. Diesel standby plants only
  2. Gas turbine peaking plants only
  3. Nuclear, large coal and run-of-river hydro plants
  4. Pumped storage plants only
Show answer & solution

Answer: (C) Nuclear, large coal and run-of-river hydro plants

They have low running cost and work best at steady output.

Question 10

Which plants are usually used to supply peak load?

  1. Run-of-river plants only
  2. Large coal plants
  3. Nuclear plants
  4. Gas turbines, storage hydro and pumped storage plants
Show answer & solution

Answer: (D) Gas turbines, storage hydro and pumped storage plants

They can start and change load quickly.

Question 11

What are fixed costs of a power plant?

  1. Costs such as interest on capital, depreciation, taxes and insurance that do not depend on energy generated
  2. Fuel costs
  3. Maintenance per unit only
  4. Lubricating oil costs
Show answer & solution

Answer: (A) Costs such as interest on capital, depreciation, taxes and insurance that do not depend on energy generated

Operating costs depend on the energy generated.

Question 12

What is a two-part tariff?

  1. A charge on connected load only
  2. A tariff with a fixed charge based on maximum demand plus a running charge based on energy consumed
  3. A flat rate per unit
  4. A free supply
Show answer & solution

Answer: (B) A tariff with a fixed charge based on maximum demand plus a running charge based on energy consumed

It is commonly used for industrial consumers.

Question 13

Why is power factor improvement important for power plants?

  1. It has no effect
  2. It reduces voltage only
  3. A low power factor increases current, losses and the size of equipment needed for the same real power
  4. It increases real power
Show answer & solution

Answer: (C) A low power factor increases current, losses and the size of equipment needed for the same real power

Capacitors are used to improve power factor.

Question 14

What is the main advantage of interconnecting power stations in a grid?

  1. Higher fuel use
  2. More breakdowns
  3. Less reliability
  4. Better reliability, reduced reserve capacity and economical sharing of load
Show answer & solution

Answer: (D) Better reliability, reduced reserve capacity and economical sharing of load

Pakistan's national grid is operated by the national transmission company.

Question 15

Which organisation regulates electricity tariffs in Pakistan?

  1. PAEC
  2. NEPRA (National Electric Power Regulatory Authority)
  3. PCB
  4. WAPDA
Show answer & solution

Answer: (B) NEPRA (National Electric Power Regulatory Authority)

It sets tariffs and licenses power companies.

Question 16

What is connected load?

  1. The maximum demand
  2. The sum of the rated capacities of all electrical appliances connected to the supply
  3. The energy consumed
  4. The average load
Show answer & solution

Answer: (B) The sum of the rated capacities of all electrical appliances connected to the supply

Maximum demand is usually less than connected load.

Question 17

What is maximum demand?

  1. The highest load drawn by a consumer or system during a given period
  2. The minimum load
  3. The average load
  4. The connected load
Show answer & solution

Answer: (A) The highest load drawn by a consumer or system during a given period

It decides the size of generating plant needed.

Question 18

What is reserve capacity of a power station?

  1. The capacity of the smallest unit
  2. Installed capacity in excess of maximum demand, kept for breakdowns, maintenance and future growth
  3. The fuel stored
  4. The capacity used at average load
Show answer & solution

Answer: (B) Installed capacity in excess of maximum demand, kept for breakdowns, maintenance and future growth

Spinning reserve is capacity kept running and ready.

Question 19

What is the effect of a high load factor on the cost of generation?

  1. It reduces the cost per unit of energy
  2. It doubles fuel cost
  3. It has no effect
  4. It increases the cost per unit
Show answer & solution

Answer: (A) It reduces the cost per unit of energy

Fixed costs are spread over more units.

Question 20

What is depreciation in power plant economics?

  1. The cost of fuel
  2. The cost of labour
  3. The decrease in value of plant and equipment with time, for which money is set aside
  4. An increase in plant value
Show answer & solution

Answer: (C) The decrease in value of plant and equipment with time, for which money is set aside

Straight-line and sinking-fund methods are common.

Question 21

What is a flat-rate tariff?

  1. A tariff with blocks of different rates
  2. A tariff based on maximum demand
  3. A free supply
  4. A tariff in which a fixed rate is charged per unit of energy consumed
Show answer & solution

Answer: (D) A tariff in which a fixed rate is charged per unit of energy consumed

It is simple but does not reflect the cost of supply.

Question 22

What is a block-rate tariff?

  1. A demand charge only
  2. A charge on connected load only
  3. A tariff in which energy is charged at different rates for successive blocks of consumption
  4. A single fixed rate per unit
Show answer & solution

Answer: (C) A tariff in which energy is charged at different rates for successive blocks of consumption

Pakistani domestic tariffs use slabs of units.

Question 23

What is a peak load plant?

  1. A plant for base load only
  2. A plant that runs only during periods of highest demand
  3. A plant that never runs
  4. A plant that runs continuously at full load
Show answer & solution

Answer: (B) A plant that runs only during periods of highest demand

Peaking plants have low capital cost but may have higher running cost.

Question 24

What is the plant use factor?

  1. The ratio of average to maximum load
  2. The fuel use per hour
  3. The ratio of connected load to demand
  4. The ratio of energy produced to the product of plant capacity and the hours the plant actually operated
Show answer & solution

Answer: (D) The ratio of energy produced to the product of plant capacity and the hours the plant actually operated

It shows how fully the plant is used while running.

Question 25

Why is a load duration curve useful in plant selection?

  1. It shows how long each level of load lasts, helping divide demand between base and peak plants
  2. It shows voltage variation
  3. It shows the fuel cost
  4. It shows plant efficiency
Show answer & solution

Answer: (A) It shows how long each level of load lasts, helping divide demand between base and peak plants

The bottom part represents base load and the top part peak load.

Practice these 25 questions interactively →