Question 1

What is the principle of a venturi meter?

  1. It measures weight of fluid
  2. It uses magnetic induction
  3. It measures velocity by a rotating float
  4. A converging section raises velocity and lowers pressure, and the pressure difference indicates flow rate
Show answer & solution

Answer: (D) A converging section raises velocity and lowers pressure, and the pressure difference indicates flow rate

Bernoulli's equation and continuity are applied.

Question 2

What is the typical discharge coefficient of a venturi meter?

  1. About 0.3
  2. About 0.61
  3. About 0.98
  4. About 1.5
Show answer & solution

Answer: (C) About 0.98

Its gradual shape keeps losses small.

Question 3

What is the typical discharge coefficient of a sharp-edged orifice meter?

  1. About 0.2
  2. About 0.61
  3. About 0.98
  4. About 1.0
Show answer & solution

Answer: (B) About 0.61

Contraction of the jet at the vena contracta lowers it.

Question 4

Why is the permanent pressure loss higher in an orifice meter than in a venturi meter?

  1. The sudden expansion after the orifice dissipates much energy
  2. The orifice uses mercury
  3. The orifice is longer
  4. The venturi has a smaller throat
Show answer & solution

Answer: (A) The sudden expansion after the orifice dissipates much energy

Orifices are cheap but waste more pumping energy.

Question 5

What is the vena contracta?

  1. The inlet of a pipe
  2. The section of minimum jet area just downstream of an orifice
  3. The outlet of a pump
  4. The throat of a venturi
Show answer & solution

Answer: (B) The section of minimum jet area just downstream of an orifice

Velocity is maximum and pressure minimum there.

Question 6

What is the coefficient of discharge of an orifice?

  1. The sum of the two coefficients
  2. The friction factor
  3. The product of the coefficient of contraction and the coefficient of velocity
  4. The ratio of pipe area to orifice area
Show answer & solution

Answer: (C) The product of the coefficient of contraction and the coefficient of velocity

Cd = Cc × Cv.

Question 7

How does flow through an orifice or venturi meter depend on the measured differential pressure?

  1. Flow is proportional to the square of differential pressure
  2. Flow is independent of differential pressure
  3. Flow is proportional to the differential pressure
  4. Flow is proportional to the square root of the differential pressure
Show answer & solution

Answer: (D) Flow is proportional to the square root of the differential pressure

This gives limited rangeability, about 3:1 to 4:1.

Question 8

What does a Pitot tube measure?

  1. Local point velocity from the difference between stagnation and static pressure
  2. Pipe roughness
  3. Viscosity
  4. Average flow rate directly
Show answer & solution

Answer: (A) Local point velocity from the difference between stagnation and static pressure

V = √(2ΔP/ρ).

Question 9

What is a rotameter?

  1. A variable-area flow meter with a float rising in a tapered tube
  2. A positive displacement meter
  3. A fixed-area differential meter
  4. A Pitot tube
Show answer & solution

Answer: (A) A variable-area flow meter with a float rising in a tapered tube

The pressure drop across the float stays nearly constant.

Question 10

In a rotameter, what remains nearly constant as flow rate changes?

  1. The annular area
  2. The pressure drop across the float
  3. The float position
  4. The flow area at the inlet
Show answer & solution

Answer: (B) The pressure drop across the float

Float position changes with flow to keep the drop constant.

Question 11

Which flow meter works on Faraday's law of electromagnetic induction?

  1. Rotameter
  2. Orifice meter
  3. Coriolis meter
  4. Magnetic flow meter
Show answer & solution

Answer: (D) Magnetic flow meter

The fluid must be electrically conductive.

Question 12

Which flow meter measures mass flow directly?

  1. Rotameter
  2. Pitot tube
  3. Coriolis flow meter
  4. Venturi meter
Show answer & solution

Answer: (C) Coriolis flow meter

It also measures density.

Question 13

Which type of meter is common for household water and fuel dispensing in Pakistan?

  1. Electromagnetic meter only
  2. Hot-wire anemometer
  3. Pitot tube
  4. Positive displacement meter
Show answer & solution

Answer: (D) Positive displacement meter

It counts fixed volumes passing through.

Question 14

Which device is used to measure flow in open channels?

  1. Weir or notch
  2. Orifice meter
  3. Rotameter
  4. Pitot static tube only
Show answer & solution

Answer: (A) Weir or notch

V-notch weirs are accurate for small flows.

Question 15

How does flow over a V-notch (triangular) weir vary with head H?

  1. In proportion to H^1.5
  2. In proportion to H^2.5
  3. In proportion to H²
  4. In proportion to H
Show answer & solution

Answer: (B) In proportion to H^2.5

Rectangular weirs vary with H^1.5.

Question 16

How does flow over a rectangular weir vary with head H?

  1. In proportion to H^2.5
  2. In proportion to √H
  3. In proportion to H^1.5
  4. In proportion to H
Show answer & solution

Answer: (C) In proportion to H^1.5

Q = (2/3)Cd L √(2g) H^1.5.

Question 17

What does a hot-wire anemometer measure?

  1. Pressure
  2. Liquid level
  3. Local gas velocity from the cooling of a heated wire
  4. Density
Show answer & solution

Answer: (C) Local gas velocity from the cooling of a heated wire

It responds quickly to turbulent fluctuations.

Question 18

Which flow meter has no moving parts and uses sound waves?

  1. Ultrasonic flow meter
  2. Rotameter
  3. Gear meter
  4. Turbine meter
Show answer & solution

Answer: (A) Ultrasonic flow meter

Transit-time and Doppler types exist.

Question 19

Which flow meter counts the shedding frequency of vortices behind a bluff body?

  1. Orifice meter
  2. Rotameter
  3. Weir
  4. Vortex flow meter
Show answer & solution

Answer: (D) Vortex flow meter

Shedding frequency is proportional to velocity.

Question 20

What is the beta ratio of an orifice meter?

  1. The discharge coefficient
  2. The ratio of orifice diameter to pipe diameter
  3. The Reynolds number
  4. The ratio of pressures
Show answer & solution

Answer: (B) The ratio of orifice diameter to pipe diameter

Typical values are 0.2 to 0.7.

Question 21

Why must an orifice meter have a long straight pipe run upstream of it?

  1. To give a fully developed, undisturbed velocity profile for accurate measurement
  2. To increase the pressure drop
  3. To reduce the cost of the meter
  4. To cool the fluid
Show answer & solution

Answer: (A) To give a fully developed, undisturbed velocity profile for accurate measurement

Standards such as ISO 5167 specify the required straight lengths.

Question 22

Which international standard covers flow measurement by orifice plates, nozzles and venturi tubes in full pipes?

  1. ISO 9001
  2. IEC 60034
  3. API 650
  4. ISO 5167
Show answer & solution

Answer: (D) ISO 5167

It gives discharge coefficients and installation rules.

Question 23

Where are the pressure tappings of a venturi meter located?

  1. At the outlet only
  2. At the inlet section and at the throat
  3. At the throat and outlet
  4. On the diverging cone only
Show answer & solution

Answer: (B) At the inlet section and at the throat

The pressure difference between inlet and throat is measured.

Question 24

Why is the diverging cone of a venturi meter made longer than the converging cone?

  1. To make the meter cheaper
  2. To measure temperature
  3. To recover pressure gradually and avoid flow separation
  4. To increase pressure loss
Show answer & solution

Answer: (C) To recover pressure gradually and avoid flow separation

A divergence angle of about 5–15° is used.

Question 25

What is a turbine flow meter?

  1. A weir
  2. A differential pressure meter
  3. A variable area meter
  4. A meter in which fluid rotates a rotor whose speed is proportional to flow rate
Show answer & solution

Answer: (D) A meter in which fluid rotates a rotor whose speed is proportional to flow rate

It is accurate for clean liquids and is used in fuel custody transfer.

Question 26

What is the rangeability (turndown) of a flow meter?

  1. Its pressure loss
  2. The ratio of maximum to minimum flow it can measure accurately
  3. Its cost
  4. Its size
Show answer & solution

Answer: (B) The ratio of maximum to minimum flow it can measure accurately

Magnetic and Coriolis meters have high turndown.