What causes natural ventilation in mines?
Show answer & solution
Answer: (C) Difference in air density between downcast and upcast shafts, mainly due to temperature
Warm, light air rises in the upcast and cool air sinks in the downcast.
Mining Engineering · Mine Ventilation & Environment
37 questions, each with the answer and a worked solution.
Practice interactively and track your score →What causes natural ventilation in mines?
Answer: (C) Difference in air density between downcast and upcast shafts, mainly due to temperature
Warm, light air rises in the upcast and cool air sinks in the downcast.
What is a downcast shaft?
Answer: (A) A shaft through which fresh air enters the mine
Downcast shafts carry intake air.
What is an upcast shaft?
Answer: (D) A shaft through which return air leaves the mine
The main exhaust fan is usually at the upcast shaft.
What is a forcing (blowing) ventilation system?
Answer: (C) The main fan pushes air into the mine, raising the pressure above atmospheric
Forcing systems are common in metal mines.
What is an exhausting ventilation system?
Answer: (D) The main fan draws air out of the mine, keeping the workings below atmospheric pressure
Exhausting systems are common in gassy coal mines.
Why are exhausting systems often preferred in gassy coal mines?
Answer: (A) If the fan stops, mine pressure rises and temporarily slows gas emission from the goaf
Air locks are needed at the upcast for hoisting.
In which ventilation layout are the downcast and upcast shafts at opposite ends of the mine property?
Answer: (B) Boundary ventilation
Boundary systems reduce leakage between intake and return.
In which ventilation layout are the downcast and upcast shafts close together near the centre of the property?
Answer: (B) Central ventilation
Central systems need good separation of intake and return airways.
What is ascensional ventilation?
Answer: (A) Air flows upward through the working faces
Upward airflow helps remove methane and heat, which rise naturally.
What is homotropal ventilation?
Answer: (C) Air and mineral flow in the same direction along the airway
Antitropal ventilation has air and coal moving in opposite directions.
Which ventilation is used for blind headings that the main airflow cannot reach?
Answer: (D) Auxiliary ventilation with fans and ducts
Auxiliary fans deliver air to the face through ducting.
What is a forcing auxiliary ventilation system?
Answer: (B) A fan blows fresh air through a duct to the face, and contaminated air returns along the heading
Forcing systems give a strong air jet at the face.
What is an exhausting auxiliary ventilation system?
Answer: (A) A fan draws air from the face through a duct, and fresh air enters along the heading
Exhaust systems keep dust and fumes out of the roadway.
What is an overlap auxiliary system?
Answer: (C) A combination of forcing and exhausting ducts used together at the face
Overlap systems give good face ventilation and dust capture.
What is the purpose of a ventilation door underground?
Answer: (D) To stop or control airflow while allowing passage of people and vehicles
Doors are often fitted in pairs to form an air lock.
What is an air lock in mine ventilation?
Answer: (B) Two doors spaced apart so that one is always closed when people pass
Air locks prevent short-circuiting of air.
What is a regulator in mine ventilation?
Answer: (D) An adjustable opening in a door or wall that adds resistance to reduce airflow in a split
Regulators balance airflow between splits.
What is a stopping in mine ventilation?
Answer: (C) A permanent wall that blocks airflow through an unused connection
Stoppings separate intake and return airways.
What is an air crossing (overcast)?
Answer: (A) A structure that lets one airway pass over another without the air mixing
Air crossings are used where intake and return airways cross.
What is a booster fan?
Answer: (C) An underground fan installed in series with the main fan to boost airflow in a district
Booster fans must be carefully planned to avoid recirculation.
What is recirculation in mine ventilation?
Answer: (A) Return air re-entering the intake air of the same district
Uncontrolled recirculation can build up gas and dust.
What is ventilation leakage?
Answer: (D) Air flowing from intake to return without passing through the working places
Leakage through stoppings and doors wastes fan power.
What is brattice cloth used for?
Answer: (B) Temporary partitions to direct air to the working face
Brattice divides a roadway into intake and return sides.
What is the main advantage of splitting the air into several districts?
Answer: (D) Each district gets fresh air, and contaminants from one district do not pass to another
Splitting also reduces mine resistance.
Which instrument commonly measures air velocity in mine airways?
Answer: (C) Vane anemometer
The anemometer is traversed across the airway to get mean velocity.
How is very low air velocity measured underground?
Answer: (A) By timing a cloud of smoke from a smoke tube over a known distance
Smoke tubes also show air direction.
How is air quantity calculated from velocity in an airway?
Answer: (B) Q = mean velocity × cross-sectional area
For example, 2 m/s × 12 m² = 24 m³/s.
What is the air quantity in an airway of 12 m² cross-section with a mean air velocity of 2 m/s?
Answer: (C) 24 m³/s
Q = 2 × 12 = 24 m³/s.
What is a ventilation survey?
Answer: (A) Measurement of airflow, pressure and air quality throughout the mine
Pressure–quantity surveys are used to calibrate network models.
What is ventilation on demand?
Answer: (B) Adjusting airflow to areas according to the equipment and people present
It saves energy in large mechanised mines.
What is controlled recirculation?
Answer: (D) Deliberately recirculating a planned portion of air with continuous monitoring
It is allowed only under strict monitoring and approval.
What is a district in mine ventilation?
Answer: (C) A section of the mine ventilated by its own split of air
Each district has its own intake and return airways.
Why should intake and return airways be kept well separated?
Answer: (D) To prevent leakage and short-circuiting of air
Good separation delivers fresh air to the faces efficiently.
What is the purpose of an air measuring station in a main airway?
Answer: (C) To provide a fixed, regular section for repeated airflow measurements
Measuring stations give accurate and comparable readings.
Why must auxiliary ventilation ducts be kept close to the face?
Answer: (B) So that fresh air reaches the face and clears gas and fumes
The duct outlet must be within a specified distance of the face.
What happens if a ventilation door is left open between intake and return?
Answer: (A) Air short-circuits and the working places beyond receive less air
Doors must be self-closing and kept shut.
What is a bleeder system in longwall coal mines?
Answer: (D) Airways that ventilate the goaf edge to carry methane away from the workings
Bleeders help prevent methane build-up near the face.