What is a magazine in blasting terms?
Show answer & solution
Answer: (D) A specially built and licensed store for explosives
Magazines must meet construction, distance and security rules.
Mining Engineering · Explosives & Blasting
37 questions, each with the answer and a worked solution.
Practice interactively and track your score →What is a magazine in blasting terms?
Answer: (D) A specially built and licensed store for explosives
Magazines must meet construction, distance and security rules.
Why must detonators be stored separately from other explosives?
Answer: (B) An accident with detonators could set off the main explosives
Separate stores or compartments limit the effect of an accident.
Why is a lightning conductor fitted to an explosives magazine?
Answer: (A) To protect the magazine from lightning strikes
Lightning protection is a standard magazine requirement.
Which department in Pakistan licenses the storage and use of explosives under the Explosives Act?
Answer: (B) Department of Explosives, headed by the Chief Inspector of Explosives
The department issues licences and inspects magazines.
Why should explosives be issued from the magazine on a first-in, first-out basis?
Answer: (A) To use older stock before it deteriorates
Stock rotation keeps explosives within their shelf life.
What is exudation in old nitroglycerine explosives?
Answer: (D) Leakage of liquid nitroglycerine from cartridges, making them very sensitive
Exuded explosives must be destroyed by experts.
Why should detonators and explosives not be carried in the same container?
Answer: (D) An accident with a detonator could set off the explosive
Separate approved containers are used underground.
What is an underground store of explosives for daily use called?
Answer: (C) Underground magazine (reserve station)
Reserve stations hold limited quantities near the workings.
What is a misfire?
Answer: (B) A charge that fails to explode wholly or partly when fired
Misfires leave dangerous unexploded explosive in the ground.
Which of these is a common cause of misfire?
Answer: (A) A broken or poorly connected initiation circuit
Other causes include cut-offs, faulty detonators and water damage.
What is a hang-fire?
Answer: (A) A charge that fires after a delay longer than expected
Hang-fires are why waiting times are required after misfires.
Why must persons wait a prescribed time before approaching a misfire fired with safety fuse?
Answer: (B) The fuse may still be burning slowly and could cause a hang-fire
Regulations prescribe longer waits for fuse firing than for electric firing.
Why is the waiting time after an electric misfire usually shorter than after a fuse misfire?
Answer: (D) There is no slow-burning fuse that might still be smouldering
The circuit is disconnected and shunted before approaching.
What is an accepted method of dealing with a misfired hole?
Answer: (C) Firing a new relieving hole drilled parallel at a safe distance, or re-priming after carefully removing stemming
Only the shotfirer handles misfires under the mine's procedures.
Why must drilling into old sockets (bootlegs) be avoided?
Answer: (C) They may contain unexploded explosive
Sockets must be examined and never drilled into.
What is a bootleg (socket) in blasting?
Answer: (B) The remaining bottom part of a hole after blasting that may hold unexploded charge
Bootlegs show the hole did not break fully.
Who is authorised to charge and fire shots in a mine?
Answer: (A) A competent certified shotfirer (blaster)
Shotfirers hold certificates under mine regulations.
Why are warning signals given before a blast?
Answer: (D) To make sure everyone has cleared the danger zone
Sirens or horns are sounded before firing and at all clear.
Why are all approaches to a blast area guarded before firing?
Answer: (D) To stop anyone entering the danger zone
Guards stay posted until the all-clear signal.
Why does a shotfirer count the shots when firing by safety fuse?
Answer: (B) To detect any misfires
If fewer shots are heard than were lit, a misfire is assumed.
How should deteriorated or damaged explosives be disposed of?
Answer: (A) By burning or detonation under expert supervision in line with regulations
Disposal must follow the manufacturer's and Department of Explosives' instructions.
Which items are prohibited inside an explosives magazine?
Answer: (C) Matches, lighters and spark-producing tools
Fire and sparks are the greatest risks in a magazine.
Why should the floor of an explosives magazine be free of exposed iron or steel?
Answer: (C) To avoid sparks
Spark-proof floors and fittings reduce ignition risk.
What is the purpose of quantity–distance tables for magazines?
Answer: (B) To set safe separation distances from buildings, roads and other magazines based on the quantity stored
Larger quantities require larger distances.
Why is a register of explosives kept at the magazine?
Answer: (D) To account for every unit received, issued, used and returned
Accurate records prevent theft and loss.
What must be done with unused explosives at the end of a shift?
Answer: (A) Return them to the magazine and record them
Explosives must never be left unattended.
Which tool should be used to push explosive cartridges into a blast hole?
Answer: (A) A wooden or non-sparking tamping rod
Steel tools can cause sparks or impact detonation.
Which hazard must be controlled when ANFO is loaded pneumatically?
Answer: (D) Static electricity
Semi-conductive hoses and earthing reduce static build-up.
Why is special care needed when charging hot holes, such as in burning coal or reactive sulphide ore?
Answer: (B) Heat may cause premature explosion of the charge
Hot or reactive holes need special products and procedures.
What is sleep time in blasting?
Answer: (C) The time loaded holes remain before firing
Sleep time is limited by explosive type and ground conditions.
Why should sleep time of loaded holes be kept as short as possible?
Answer: (D) Water, ground movement or reactive ground may damage or desensitise the charge
Long sleep time increases the risk of misfires.
Where should primers be made up?
Answer: (B) At the blast site just before charging, away from the magazine
Making primers at the hole limits handling of armed charges.
Why is a blast report (blasting log) prepared after each blast?
Answer: (A) To record design, charges, results and incidents for safety and improvement
Blast records are required by regulations and help analyse problems.
Which explosive accessory must be checked and its condition recorded before use in electric blasting?
Answer: (C) The exploder and circuit tester
Faulty exploders or testers can cause misfires or accidents.
What should be done if a shotfirer finds damaged packaging or leaking explosive in a delivery?
Answer: (C) Set it aside, report it and do not use it until assessed
Damaged explosives can be more sensitive and must be handled by experts.
Why must vehicles carrying explosives display warning signs and carry fire extinguishers?
Answer: (C) To warn others and allow small fires to be put out before they reach the explosives
Transport rules under the Explosives Act specify vehicle requirements.
What is the purpose of a blast exclusion (danger) zone?
Answer: (B) To keep people and equipment outside the area where flyrock and other blast effects can reach
The zone size depends on blast design and site conditions.