What is pool boiling?
Show answer & solution
Answer: (B) Boiling of a liquid at rest on a heated surface, with motion caused only by natural convection and bubbles
A kettle shows pool boiling.
Mechanical Engineering · Heat Transfer
27 questions, each with the answer and a worked solution.
Practice interactively and track your score →What is pool boiling?
Answer: (B) Boiling of a liquid at rest on a heated surface, with motion caused only by natural convection and bubbles
A kettle shows pool boiling.
What are the main regimes of pool boiling as wall superheat increases?
Answer: (A) Natural convection, nucleate boiling, transition boiling and film boiling
They are shown on the boiling curve.
In which boiling regime is the heat transfer coefficient highest?
Answer: (D) Nucleate boiling
Bubbles cause intense mixing near the surface.
What is the critical (peak) heat flux in boiling?
Answer: (B) The maximum heat flux at the end of nucleate boiling, beyond which a vapour film begins to form
Exceeding it in heat-flux-controlled systems can cause burnout.
What is film boiling?
Answer: (A) Boiling in which a continuous vapour film covers the heated surface and heat transfer is poor
Radiation through the film becomes important at high temperatures.
What is the Leidenfrost point?
Answer: (D) The point of minimum heat flux on the boiling curve where stable film boiling begins
Water drops dance on a very hot plate due to this effect.
What is flow boiling?
Answer: (C) Boiling of a liquid flowing through a heated channel or tube
Boiler tubes and evaporators involve flow boiling.
What is filmwise condensation?
Answer: (D) Condensation in which the condensate forms a continuous liquid film on the surface
It is the usual mode on clean, wettable surfaces.
What is dropwise condensation?
Answer: (A) Condensation in which vapour condenses as droplets that roll off, leaving bare surface
It occurs on non-wetting surfaces.
How does the heat transfer coefficient of dropwise condensation compare with filmwise condensation?
Answer: (C) It is several times higher
The liquid film adds thermal resistance in filmwise condensation.
Why is filmwise condensation usually assumed in condenser design?
Answer: (B) Dropwise condensation is hard to maintain for long periods
Promoters for dropwise condensation wear off.
What is the effect of non-condensable gases such as air on condensation?
Answer: (A) They greatly reduce the condensation heat transfer coefficient
Condensers have air ejectors to remove them.
Who developed the classical theory of laminar film condensation on a vertical plate?
Answer: (C) Wilhelm Nusselt
It assumes a thin laminar condensate film.
What is total heat of steam?
Answer: (D) The heat required to convert water into steam and superheat it, measured from a reference state
It is the enthalpy of the steam.
What is sensible heat?
Answer: (B) Heat that raises the temperature of a substance without change of phase
Latent heat changes phase at constant temperature.
What is subcooled (local) boiling?
Answer: (D) Boiling in which bubbles form at the hot surface but collapse in the cooler bulk liquid
The bulk liquid is below saturation temperature.
What is saturated boiling?
Answer: (A) Boiling in which the bulk liquid is at its saturation temperature
Bubbles rise to the free surface without collapsing.
What is wall superheat in boiling?
Answer: (B) The difference between the heated surface temperature and the saturation temperature of the liquid
Boiling regimes depend on wall superheat.
What is burnout in boiling heat transfer?
Answer: (B) Sudden rise in wall temperature when heat flux exceeds the critical value and a vapour film forms
It can damage boiler tubes and nuclear fuel rods.
What factors increase the critical heat flux in boiling?
Answer: (A) Higher pressure (up to a point), flow velocity and wettable surfaces
Engineers keep heat flux below the critical value.
What is the main use of promoters in condensers?
Answer: (C) To encourage dropwise condensation
Promoters make the surface non-wetting.
How does the thickness of the condensate film on a vertical tube change from top to bottom?
Answer: (D) It increases
More condensate accumulates as the film flows down.
Why are horizontal tubes often preferred to vertical tubes in condensers?
Answer: (A) The condensate film stays thinner, giving higher heat transfer coefficients
The condensate drips off horizontal tubes quickly.
What is a steam trap?
Answer: (B) A device that removes condensate and non-condensable gases from steam lines without letting steam escape
It improves heat transfer in steam heaters.
What is the latent heat of vaporisation of water at atmospheric pressure, approximately?
Answer: (D) 2257 kJ/kg
The latent heat of fusion of ice is about 334 kJ/kg.
What is evaporation?
Answer: (C) Change of liquid into vapour at its free surface at any temperature below boiling
Evaporation cools the remaining liquid.
How does pressure affect the boiling point of water?
Answer: (D) Higher pressure raises the boiling point
Pressure cookers use this effect.