Power System Protection: Equipment Protection

Electrical Engineering · Power System Protection

34 questions, each with the answer and a worked solution.

Practice interactively and track your score →
Question 1

Which device protects oil-filled transformers against faults that produce gas inside the tank?

  1. Induction relay
  2. Undercurrent relay
  3. Buchholz relay
  4. Impedance relay
Show answer & solution

Answer: (C) Buchholz relay

It is fitted in the pipe between the main tank and conservator.

Question 2

What does the alarm float of a Buchholz relay respond to?

  1. Low oil temperature
  2. A severe internal short circuit only
  3. Overvoltage
  4. Slow accumulation of gas from minor (incipient) faults
Show answer & solution

Answer: (D) Slow accumulation of gas from minor (incipient) faults

A severe fault causes an oil surge that operates the trip float.

Question 3

Which transformers are normally fitted with Buchholz relays?

  1. Dry-type transformers
  2. Oil-immersed transformers with conservators, usually above about 500 kVA
  3. Instrument transformers only
  4. All small distribution transformers below 25 kVA
Show answer & solution

Answer: (B) Oil-immersed transformers with conservators, usually above about 500 kVA

Sealed and dry transformers use other protection.

Question 4

What is the main protection against internal phase faults in large power transformers?

  1. Differential protection
  2. Fuses
  3. Over-voltage relay
  4. Buchholz relay only
Show answer & solution

Answer: (A) Differential protection

It compares currents on the HV and LV sides.

Question 5

Why is second-harmonic restraint used in transformer differential protection?

  1. To detect lightning
  2. To prevent tripping on magnetising inrush current, which is rich in second harmonics
  3. To increase sensitivity to through faults
  4. To measure load
Show answer & solution

Answer: (B) To prevent tripping on magnetising inrush current, which is rich in second harmonics

Inrush flows only in the energised winding.

Question 6

How are the CTs usually connected on the star side of a delta–star transformer for differential protection with electromechanical relays?

  1. In star
  2. In zig-zag
  3. In delta
  4. In open delta
Show answer & solution

Answer: (C) In delta

This corrects for the 30° phase shift and zero sequence current; numerical relays do it in software.

Question 7

What is restricted earth fault (REF) protection of a transformer?

  1. Protection against low oil level
  2. Protection against lightning
  3. Overload protection
  4. Sensitive protection against earth faults in a star winding, using the neutral CT and line CTs
Show answer & solution

Answer: (D) Sensitive protection against earth faults in a star winding, using the neutral CT and line CTs

REF detects faults close to the neutral.

Question 8

What does the winding temperature indicator (WTI) of a transformer do?

  1. It measures oil level
  2. It measures gas
  3. It measures voltage
  4. It measures simulated hot-spot winding temperature and gives alarms, trips and fan control
Show answer & solution

Answer: (D) It measures simulated hot-spot winding temperature and gives alarms, trips and fan control

An oil temperature indicator (OTI) measures top oil temperature.

Question 9

What is the purpose of a pressure relief device on a transformer?

  1. To release dangerous internal pressure from a severe fault and protect the tank
  2. To fill oil
  3. To cool oil
  4. To measure current
Show answer & solution

Answer: (A) To release dangerous internal pressure from a severe fault and protect the tank

It operates within milliseconds.

Question 10

Which protection is the main protection against stator phase faults in large generators?

  1. Buchholz relay
  2. Over-speed device
  3. Generator differential protection
  4. Reverse power relay
Show answer & solution

Answer: (C) Generator differential protection

It operates fast and is stable for external faults.

Question 11

Why is 100% stator earth fault protection needed for large generators?

  1. Earth faults never occur
  2. Conventional schemes cannot detect earth faults near the neutral end of the winding
  3. To protect against overload
  4. To detect overspeed
Show answer & solution

Answer: (B) Conventional schemes cannot detect earth faults near the neutral end of the winding

Third-harmonic or injection methods cover the last part of the winding.

Question 12

Which protection is used against overspeed of a turbine-generator?

  1. Distance relay
  2. Earth fault relay
  3. Mechanical and electrical overspeed trips
  4. Buchholz relay
Show answer & solution

Answer: (C) Mechanical and electrical overspeed trips

Overspeed may follow sudden loss of load.

Question 13

Which protection is used for busbars in large substations?

  1. Fuse protection
  2. High-impedance or low-impedance busbar differential protection
  3. Thermal protection only
  4. Buchholz protection
Show answer & solution

Answer: (B) High-impedance or low-impedance busbar differential protection

Busbar faults are rare but very serious.

Question 14

Which is the main protection for 11 kV radial distribution feeders?

  1. Overcurrent and earth fault relays
  2. Distance protection
  3. Buchholz relay
  4. Busbar differential
Show answer & solution

Answer: (A) Overcurrent and earth fault relays

IDMT relays are graded along the feeder.

Question 15

Which is the main protection used for 220 kV and 500 kV transmission lines?

  1. Fuses
  2. Thermal relays only
  3. Buchholz relays
  4. Distance protection with communication-aided schemes and line differential protection
Show answer & solution

Answer: (D) Distance protection with communication-aided schemes and line differential protection

Fast clearing is essential for stability.

Question 16

What protection is commonly used for large capacitor banks?

  1. Distance protection
  2. Buchholz relay
  3. Reverse power relay
  4. Unbalance (neutral current or voltage) protection and overcurrent protection
Show answer & solution

Answer: (D) Unbalance (neutral current or voltage) protection and overcurrent protection

Unbalance detects failure of individual capacitor units.

Question 17

Which protection prevents damage to a motor whose rotor is locked during starting?

  1. Buchholz protection
  2. Locked-rotor (stall) protection
  3. Distance protection
  4. Surge arrester
Show answer & solution

Answer: (B) Locked-rotor (stall) protection

Locked rotor current is several times full-load current.

Question 18

What is the purpose of under-voltage protection for large motors?

  1. To increase speed
  2. To limit inrush current to zero
  3. To disconnect motors on loss of supply to prevent damage and uncontrolled restart
  4. To improve power factor
Show answer & solution

Answer: (C) To disconnect motors on loss of supply to prevent damage and uncontrolled restart

Many motors restarting together could overload the system.

Question 19

What does loss-of-excitation protection protect a generator against?

  1. Running as an induction generator drawing reactive power, which overheats the rotor and stator
  2. Low oil level
  3. Over-speed only
  4. Lightning
Show answer & solution

Answer: (A) Running as an induction generator drawing reactive power, which overheats the rotor and stator

The relay uses an offset mho characteristic.

Question 20

What does inter-turn fault protection detect in machines?

  1. Overloads
  2. Over-voltages from lightning
  3. Phase-to-earth faults only
  4. Short circuits between turns of the same winding
Show answer & solution

Answer: (D) Short circuits between turns of the same winding

Inter-turn faults may not be seen by differential protection.

Question 21

Which protection is used against transformer overloading?

  1. Thermal overload protection using temperature indicators
  2. Reverse power relay
  3. Distance protection
  4. Busbar protection
Show answer & solution

Answer: (A) Thermal overload protection using temperature indicators

Overloading accelerates insulation ageing.

Question 22

Why is pole slipping protection used for large generators?

  1. To control voltage
  2. To trip a generator that has lost synchronism with the system
  3. To start the generator
  4. To measure energy
Show answer & solution

Answer: (B) To trip a generator that has lost synchronism with the system

Pole slipping causes large current and torque pulsations.

Question 23

What is the function of a sudden pressure relay on a transformer?

  1. To measure voltage
  2. To control fans
  3. To detect a rapid rise in internal pressure from internal faults
  4. To measure oil level
Show answer & solution

Answer: (C) To detect a rapid rise in internal pressure from internal faults

It is used in sealed transformers without conservators.

Question 24

Which protection is used to detect a broken conductor on a feeder?

  1. Surge arrester
  2. Buchholz relay
  3. Negative-sequence to positive-sequence current ratio protection
  4. Thermal relay
Show answer & solution

Answer: (C) Negative-sequence to positive-sequence current ratio protection

A broken conductor causes unbalance without large overcurrent.

Question 25

What protection is used for HV motors against earth faults?

  1. Buchholz relay
  2. Reverse power relay
  3. Distance relay
  4. Sensitive earth fault protection using core-balance CTs
Show answer & solution

Answer: (D) Sensitive earth fault protection using core-balance CTs

Motor earth faults must be cleared quickly to limit core damage.

Question 26

What is the purpose of transformer through-fault protection?

  1. To protect against oil leaks
  2. To protect the transformer against damage from long external faults
  3. To protect against lightning
  4. To start the transformer
Show answer & solution

Answer: (B) To protect the transformer against damage from long external faults

Through faults cause mechanical and thermal stress on windings.

Question 27

Why do differential relays for transformers need ratio correction?

  1. CTs have no ratio
  2. CT ratios rarely match exactly the transformer ratio on both sides
  3. Transformers have no ratio
  4. To increase fault current
Show answer & solution

Answer: (B) CT ratios rarely match exactly the transformer ratio on both sides

Interposing CTs or numerical settings correct mismatch.

Question 28

What does over-excitation (V/f) protection of a transformer prevent?

  1. Lightning
  2. Earth faults only
  3. Core overheating due to excessive flux at high voltage or low frequency
  4. Oil leaks
Show answer & solution

Answer: (C) Core overheating due to excessive flux at high voltage or low frequency

It is important for generator step-up transformers.

Question 29

What protection protects the generator rotor field winding against earth faults?

  1. Buchholz
  2. Stator differential
  3. Reverse power
  4. Rotor earth fault protection
Show answer & solution

Answer: (D) Rotor earth fault protection

A single rotor earth fault is not dangerous, but a second one is.

Question 30

Which protection is used to trip a generator when its prime mover fails and it begins to motor?

  1. Negative-sequence protection
  2. Reverse power protection
  3. Distance protection
  4. Over-voltage protection
Show answer & solution

Answer: (B) Reverse power protection

Motoring power for steam turbines is only a few percent of rating.

Question 31

Which is the simplest protection for small distribution transformers on poles?

  1. Drop-out fuses on the HV side and fuses or breakers on the LV side
  2. Generator differential
  3. Busbar differential
  4. Distance relays
Show answer & solution

Answer: (A) Drop-out fuses on the HV side and fuses or breakers on the LV side

Surge arresters are also fitted on the HV side.

Question 32

What is high-impedance busbar differential protection based on?

  1. A low-voltage fuse
  2. Thermal relays
  3. A voltage-operated relay across paralleled CTs that stays stable for through faults
  4. Distance zones
Show answer & solution

Answer: (C) A voltage-operated relay across paralleled CTs that stays stable for through faults

It is simple and very stable when CTs are matched.

Question 33

What is the function of a neutral displacement (residual voltage) relay?

  1. To measure frequency
  2. To detect lightning
  3. To detect earth faults in unearthed or high-impedance earthed systems
  4. To detect overload
Show answer & solution

Answer: (C) To detect earth faults in unearthed or high-impedance earthed systems

An earth fault shifts the neutral voltage.

Question 34

What protection is used to detect loss of mains for distributed generation such as solar plants?

  1. Busbar protection
  2. Rate of change of frequency (ROCOF) and vector shift protection
  3. Distance zone 3
  4. Buchholz relay
Show answer & solution

Answer: (B) Rate of change of frequency (ROCOF) and vector shift protection

It prevents unintended islanding of embedded generation.

Practice these 34 questions interactively →