Which conductor carries power from a substation to distribution areas without intermediate tappings?
Show answer & solution
Answer: (B) Feeder
Current in a feeder is the same along its length.
Electrical Engineering · Power Systems
35 questions, each with the answer and a worked solution.
Practice interactively and track your score →Which conductor carries power from a substation to distribution areas without intermediate tappings?
Answer: (B) Feeder
Current in a feeder is the same along its length.
What is a distributor in a distribution system?
Answer: (D) A conductor from which tappings are taken to supply consumers
Current varies along a distributor.
What are service mains?
Answer: (B) Small cables connecting a distributor to a consumer's premises
They are usually overhead drops or underground cables.
What is the main advantage of a ring main distribution system over a radial system?
Answer: (A) Better reliability because consumers can be supplied from either end
A fault can be isolated without interrupting all consumers.
What is the main disadvantage of a radial distribution system?
Answer: (B) A fault interrupts all consumers beyond it
Radial systems are simple and cheap but less reliable.
At what voltage is primary distribution commonly carried out by DISCOs in Pakistan?
Answer: (A) 11 kV
11 kV feeders supply pole-mounted distribution transformers.
At what voltages is low-voltage distribution supplied to consumers in Pakistan?
Answer: (C) 400 V three-phase and 230 V single-phase
Distribution transformers step 11 kV down to these levels.
Which company distributes electricity in most of Balochistan?
Answer: (D) QESCO
Quetta Electric Supply Company serves most of the province.
Which company supplies electricity in Lahore and surrounding districts?
Answer: (C) LESCO
Lahore Electric Supply Company is one of the largest DISCOs.
Which electricity company in Pakistan is vertically integrated, handling generation, transmission and distribution in its area?
Answer: (B) K-Electric
K-Electric serves Karachi and nearby areas.
Which body regulates the electric power sector in Pakistan, including tariffs and licences?
Answer: (A) NEPRA
The National Electric Power Regulatory Authority was set up under the NEPRA Act of 1997.
Which agency buys power from generators on behalf of DISCOs in Pakistan?
Answer: (D) Central Power Purchasing Agency (CPPA-G)
CPPA-G manages the market settlement for the national grid.
What is the voltage drop in a uniformly loaded distributor fed at one end compared with the same total load concentrated at the far end?
Answer: (B) Half
A uniformly distributed load behaves like the total load at the midpoint.
What are technical losses in a distribution system?
Answer: (A) Losses due to resistance of lines and transformers
Non-technical losses include theft and billing errors.
What are non-technical losses in electricity distribution?
Answer: (D) Losses due to theft, unmetered supply and billing errors
Reducing them is a major challenge for DISCOs.
Which measure reduces technical losses in an 11 kV distribution network?
Answer: (C) Reducing feeder length and installing capacitors to improve power factor
Shorter feeders and higher conductor size also help.
What is net metering under NEPRA regulations?
Answer: (D) A system where consumers with solar panels export surplus energy to the grid and are billed for net consumption
It encourages distributed solar generation.
What is the purpose of an advanced metering infrastructure (smart meters)?
Answer: (A) To measure and communicate consumption data remotely in real time
Smart meters help reduce losses and improve billing accuracy.
Where is a distribution transformer usually installed in Pakistani residential areas?
Answer: (C) On poles or platforms close to the load centre
Locating transformers near load reduces LV losses.
What is the function of a grid station in the distribution system?
Answer: (B) To step down transmission voltage and feed sub-transmission or distribution feeders
132/11 kV grid stations are common in DISCO networks.
Why should loads be balanced among the three phases of an LV distribution system?
Answer: (A) To reduce neutral current, losses and voltage unbalance
Unbalance overloads one phase and the neutral.
What is the purpose of a recloser on an overhead distribution feeder?
Answer: (C) To automatically reclose after temporary faults and restore supply
Most overhead faults are temporary, such as bird or branch contact.
What is an interconnected (mesh) distribution system?
Answer: (D) A network fed from several sources so that supply continues if one source fails
Mesh networks are used in dense urban areas.
What is the main advantage of underground distribution cables in cities?
Answer: (B) Better safety, appearance and reliability against weather
Underground systems cost more but suit dense areas.
What is voltage regulation in a distribution feeder concerned with?
Answer: (B) Keeping consumer voltage within permitted limits as load varies
Tap changers and capacitors help control voltage.
What do ACSR code names such as Dog, Rabbit and Osprey indicate?
Answer: (C) Standard conductor sizes and strandings
Each name represents a specific aluminium and steel combination.
Which supply system is used by Pakistani DISCOs for 11 kV distribution feeders?
Answer: (A) Three-phase three-wire
The 400 V system is three-phase four-wire with a neutral.
What does PEC stand for in Pakistan's engineering profession?
Answer: (D) Pakistan Engineering Council
PEC registers engineers and regulates the engineering profession.
What is the main function of a sub-transmission network?
Answer: (A) To carry power at intermediate voltages such as 132 kV or 66 kV from grid stations to distribution substations
It links transmission and distribution.
What is the function of a ring main unit (RMU) in underground distribution?
Answer: (C) A compact switchgear unit that allows switching and protection of cable ring circuits
RMUs are common in urban 11 kV cable networks.
Why are distribution feeders sectionalised with switches or sectionalisers?
Answer: (D) To isolate faulty sections and restore supply to healthy parts
Sectionalising improves reliability indices.
What does SAIDI measure in distribution reliability?
Answer: (A) The average duration of interruptions per customer per year
SAIFI measures average frequency of interruptions.
What is a dedicated feeder?
Answer: (C) An 11 kV feeder that supplies a single large consumer
Industries often take dedicated feeders for reliability.
What is the main purpose of a distribution capacitor bank on an 11 kV feeder?
Answer: (B) To supply reactive power locally, improving voltage and reducing losses
Capacitors reduce current in upstream lines.
What is load shedding in the Pakistani context?
Answer: (B) Planned interruption of supply to consumers when demand exceeds available supply or for loss control
Planned outages are scheduled by DISCOs.