What is the overall heat transfer coefficient U?
Show answer & solution
Answer: (D) A coefficient combining all resistances between hot and cold fluids
1/U = 1/hi + Rwall + 1/ho + fouling, on a consistent area basis.
Chemical Engineering · Heat Transfer
43 questions, each with the answer and a worked solution.
Practice interactively and track your score →What is the overall heat transfer coefficient U?
Answer: (D) A coefficient combining all resistances between hot and cold fluids
1/U = 1/hi + Rwall + 1/ho + fouling, on a consistent area basis.
How is the overall coefficient of a clean thin flat wall found from two film coefficients h₁ and h₂ when wall resistance is negligible?
Answer: (B) 1/U = 1/h₁ + 1/h₂
U is always less than the smaller film coefficient.
What is the overall coefficient when h₁ = 100 and h₂ = 100 W/(m²·K) with negligible wall resistance?
Answer: (A) 50 W/(m²·K)
1/U = 0.01 + 0.01.
Which film coefficient controls the overall coefficient?
Answer: (C) The smaller film coefficient (largest resistance)
Improving the controlling side gives the most benefit.
What is the log mean temperature difference (LMTD)?
Answer: (D) (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂)
It is used in Q = UA·LMTD.
What is the LMTD for terminal temperature differences of 60 K and 20 K?
Answer: (B) About 36.4 K
(60 − 20)/ln 3 = 40/1.0986.
What is the LMTD when the two terminal temperature differences are equal?
Answer: (C) Equal to that temperature difference
The formula becomes 0/0 and the limit is ΔT.
Why is counter-current flow preferred to co-current flow in heat exchangers?
Answer: (B) It gives a larger mean temperature difference and allows closer temperature approach
The cold outlet can exceed the hot outlet temperature in counter-current flow.
In which flow arrangement can the outlet temperature of the cold fluid exceed the outlet temperature of the hot fluid?
Answer: (D) Counter-current flow
In parallel flow the cold outlet always stays below the hot outlet.
What is the LMTD correction factor F used for?
Answer: (A) Adjusting the counter-current LMTD for multipass and cross-flow exchangers
F values below about 0.75 indicate a poor design.
What is a fouling factor?
Answer: (C) An allowance for the extra resistance due to deposits on heat transfer surfaces
TEMA lists typical fouling resistances.
Which standard is widely used for the mechanical design of shell and tube heat exchangers?
Answer: (C) TEMA standards
TEMA classes R, C and B cover severity of service.
What is the purpose of baffles on the shell side of a shell and tube exchanger?
Answer: (A) To direct shell-side fluid across the tubes, increasing velocity and heat transfer, and to support the tubes
Segmental baffles with about 25% cut are common.
Which fluid is usually placed on the tube side of a shell and tube exchanger?
Answer: (B) The more corrosive, fouling or high-pressure fluid
Tubes are easier to clean and cheaper to make in alloy.
What is the purpose of a floating head in a shell and tube exchanger?
Answer: (D) To allow differential thermal expansion between tubes and shell and permit bundle removal
Fixed tube-sheet designs may need expansion joints.
What is a U-tube heat exchanger's main advantage?
Answer: (A) Tubes can expand freely and the bundle can be removed
Inside cleaning of the U-bends is difficult.
What is the effectiveness of a heat exchanger?
Answer: (C) The ratio of actual heat transfer to the maximum possible heat transfer
ε = Q/Qmax, with Qmax = Cmin(Th,in − Tc,in).
What is NTU in heat exchanger analysis?
Answer: (D) UA/Cmin, the number of transfer units
The ε–NTU method is useful when outlet temperatures are unknown.
What is the heat capacity rate ratio C* in the ε–NTU method?
Answer: (B) Cmin/Cmax
For a condenser or evaporator C* = 0.
What is the heat duty needed to heat 2 kg/s of water from 30 °C to 70 °C (Cp = 4.18 kJ/(kg·K))?
Answer: (C) About 334 kW
Q = 2 × 4.18 × 40.
What area is needed for a duty of 400 kW with U = 500 W/(m²·K) and LMTD = 40 K?
Answer: (B) 20 m²
A = Q/(U·LMTD) = 400,000/20,000.
What is a double pipe heat exchanger?
Answer: (A) One pipe inside another, with one fluid in the inner pipe and the other in the annulus
It suits small duties and high pressures.
What is the main advantage of a plate heat exchanger?
Answer: (D) High heat transfer coefficients and compact size, with easy cleaning
Gaskets limit temperature and pressure; they are common in dairies.
Which heat exchanger is widely used in dairy pasteurisation?
Answer: (A) Plate heat exchanger
HTST pasteurisation uses plate exchangers with regeneration sections.
What is an air-cooled heat exchanger (fin-fan cooler)?
Answer: (B) An exchanger in which process fluid in finned tubes is cooled by air blown by fans
It saves cooling water in dry areas.
What is a reboiler in a distillation system?
Answer: (D) A heat exchanger that vaporises liquid at the bottom of the column
Kettle and thermosiphon reboilers are common.
What does a thermosiphon reboiler rely on for circulation?
Answer: (C) Density difference between liquid and the vapour–liquid mixture
Vertical thermosiphon reboilers are common in refineries.
What is a regenerator?
Answer: (C) A heat exchanger where hot and cold fluids flow alternately through the same matrix that stores heat
Glass furnaces and blast-furnace stoves use regenerators.
What is an economiser in a boiler?
Answer: (D) A heat exchanger that preheats boiler feedwater using flue gas
It raises boiler efficiency.
What is the purpose of an air preheater in a furnace?
Answer: (A) To heat combustion air with flue gas, saving fuel
Flue gas exit temperature must stay above the acid dew point.
Why are cooling-water outlet temperatures kept below about 45–50 °C?
Answer: (B) To limit scaling and fouling on heat exchanger surfaces
Hardness salts deposit faster at higher temperatures.
What is the jacket of a reactor vessel used for?
Answer: (C) Heating or cooling the vessel contents by fluid circulating in an outer shell
Internal coils give more area when needed.
What is the approach temperature in a heat exchanger?
Answer: (D) The smallest temperature difference between hot and cold streams
Small approaches need large areas.
How does fouling affect heat exchanger performance over time?
Answer: (B) It lowers U, reducing duty and often increasing pressure drop
Periodic cleaning restores performance.
What is a scraped-surface heat exchanger used for?
Answer: (A) Heating or cooling very viscous or crystallising products
Rotating blades keep the surface clean.
What is the typical overall coefficient for a steam-to-water shell and tube heat exchanger?
Answer: (C) About 1,000 to 3,500 W/(m²·K)
Gas-to-gas exchangers have much lower values.
What is the hot-fluid outlet temperature if 1 kg/s of oil (Cp = 2 kJ/(kg·K)) at 150 °C gives 100 kW to water?
Answer: (C) 100 °C
ΔT = 100/(1 × 2) = 50 K.
What is the maximum possible heat transfer in an exchanger with Cmin = 4 kW/K and inlet temperatures 120 °C (hot) and 20 °C (cold)?
Answer: (C) 400 kW
Qmax = Cmin × (Th,in − Tc,in).
What is the heat exchanger effectiveness if actual duty is 300 kW and maximum possible duty is 400 kW?
Answer: (C) 0.75
ε = 300/400.
What is a 1-2 shell and tube heat exchanger?
Answer: (B) An exchanger with one shell pass and two tube passes
Multi-pass designs need the LMTD correction factor.
Why is the tube pitch arranged in a triangular pattern in many exchangers?
Answer: (D) It fits more tubes in a given shell and gives higher shell-side coefficients
Square pitch is preferred where the shell side must be cleaned mechanically.
What is pinch analysis used for?
Answer: (A) Designing heat exchanger networks to minimise external heating and cooling utilities
It identifies the minimum temperature approach point between composite curves.
What is a waste heat boiler?
Answer: (A) A boiler that raises steam from hot process or flue gas
It is used after sulphur furnaces and reformers.