Engineering, Management, Agriculture and Veterinary MCQs are now live. FPSC, PPSC, EPE, IELTS & GRE coming soon.

Process Control & Instrumentation: Measuring Instruments

Chemical Engineering · Process Control & Instrumentation

37 questions, each with the answer and a worked solution.

Practice interactively and track your score →
Question 1

What is the working principle of a thermocouple?

  1. Change of resistance with temperature
  2. The Seebeck effect, a voltage produced at the junction of two dissimilar metals at different temperatures
  3. Expansion of liquid
  4. Radiation emission
Show answer & solution

Answer: (B) The Seebeck effect, a voltage produced at the junction of two dissimilar metals at different temperatures

The cold junction must be compensated.

Question 2

Which thermocouple type is most widely used for general industrial temperatures up to about 1,200 °C?

  1. Type K (chromel–alumel)
  2. Type S (platinum–rhodium)
  3. Type T (copper–constantan) only
  4. Type B only
Show answer & solution

Answer: (A) Type K (chromel–alumel)

Type S and B are used at higher temperatures.

Question 3

Which thermocouple types are used for very high temperatures such as in furnaces and glass melting?

  1. Type J
  2. Type T
  3. Type E
  4. Types R, S and B based on platinum–rhodium
Show answer & solution

Answer: (D) Types R, S and B based on platinum–rhodium

They are expensive but stable.

Question 4

What is a resistance temperature detector (RTD)?

  1. A pyrometer
  2. A thermocouple
  3. A sensor whose electrical resistance changes with temperature, usually platinum
  4. A bimetallic strip
Show answer & solution

Answer: (C) A sensor whose electrical resistance changes with temperature, usually platinum

Pt100 has 100 Ω at 0 °C.

Question 5

What is the resistance of a Pt100 RTD at 0 °C?

  1. 0 Ω
  2. 10 Ω
  3. 100 Ω
  4. 1,000 Ω
Show answer & solution

Answer: (C) 100 Ω

Pt1000 has 1,000 Ω at 0 °C.

Question 6

What is a thermistor?

  1. A semiconductor resistor with a large, often negative, temperature coefficient
  2. A bimetallic switch
  3. A thermocouple
  4. A mercury thermometer
Show answer & solution

Answer: (A) A semiconductor resistor with a large, often negative, temperature coefficient

It is very sensitive over a narrow range.

Question 7

What is the purpose of a thermowell?

  1. To store calibration data
  2. To protect a temperature sensor from the process fluid while allowing heat transfer
  3. To measure pressure
  4. To control flow
Show answer & solution

Answer: (B) To protect a temperature sensor from the process fluid while allowing heat transfer

It adds a lag to the measurement.

Question 8

Which instrument measures temperature by the bending of two bonded metals with different expansion coefficients?

  1. Bimetallic thermometer
  2. Pyrometer
  3. Thermocouple
  4. RTD
Show answer & solution

Answer: (A) Bimetallic thermometer

It is used in local gauges and thermostats.

Question 9

What is a differential pressure (DP) transmitter used for in level measurement?

  1. Measuring viscosity
  2. Measuring flow only
  3. Measuring temperature
  4. Measuring hydrostatic head of liquid to infer level
Show answer & solution

Answer: (D) Measuring hydrostatic head of liquid to infer level

Level = ΔP/(ρg); density changes cause error.

Question 10

Which level measurement uses a buoyant element whose apparent weight changes with level?

  1. Ultrasonic gauge
  2. Displacer level transmitter
  3. Capacitance probe
  4. Radar level gauge
Show answer & solution

Answer: (B) Displacer level transmitter

Floats follow the surface instead.

Question 11

Which non-contact level measurement uses microwaves reflected from the liquid surface?

  1. DP cell
  2. Bubbler
  3. Radar level transmitter
  4. Displacer
Show answer & solution

Answer: (C) Radar level transmitter

It is unaffected by vapour and temperature changes.

Question 12

What is a bubbler (purge) level system?

  1. A radar gauge
  2. A float system
  3. A sight glass
  4. A system that measures the back-pressure of air bubbled through a dip tube to find level
Show answer & solution

Answer: (D) A system that measures the back-pressure of air bubbled through a dip tube to find level

It suits corrosive or slurry liquids.

Question 13

What is a sight glass?

  1. A transparent tube or window showing liquid level directly
  2. A radar gauge
  3. A pressure gauge
  4. A flow meter
Show answer & solution

Answer: (A) A transparent tube or window showing liquid level directly

It is used for local indication.

Question 14

What is a nuclear (radiation) level gauge suited for?

  1. Measuring flow
  2. Level measurement in highly corrosive, hot or high-pressure vessels without contact
  3. Measuring temperature
  4. Low-cost water tanks only
Show answer & solution

Answer: (B) Level measurement in highly corrosive, hot or high-pressure vessels without contact

A source and detector are placed outside the vessel.

Question 15

Which device converts pressure into electrical signal using a deforming diaphragm?

  1. Thermocouple
  2. Pressure transmitter with strain gauge or capacitive sensor
  3. Bimetal
  4. Rotameter
Show answer & solution

Answer: (B) Pressure transmitter with strain gauge or capacitive sensor

Smart transmitters also send digital diagnostics.

Question 16

What is the standard analogue signal range for electronic process transmitters?

  1. 0 to 10 V only
  2. 0 to 100 mA
  3. 1 to 5 A
  4. 4 to 20 mA
Show answer & solution

Answer: (D) 4 to 20 mA

A 4 mA live zero helps detect broken wires.

Question 17

What is the standard pneumatic signal range for process instruments?

  1. 0 to 100 psi
  2. 1 to 3 psi
  3. 3 to 15 psi (about 0.2 to 1.0 bar)
  4. 10 to 50 psi
Show answer & solution

Answer: (C) 3 to 15 psi (about 0.2 to 1.0 bar)

Pneumatic valves are still widely used.

Question 18

What does a 12 mA signal represent on a 4–20 mA transmitter with range 0–200 °C?

  1. 50 °C
  2. 60 °C
  3. 100 °C
  4. 120 °C
Show answer & solution

Answer: (C) 100 °C

12 mA is 50% of the 16 mA span.

Question 19

Which instrument measures pH?

  1. A glass electrode with a reference electrode
  2. A thermocouple
  3. A DP cell
  4. A rotameter
Show answer & solution

Answer: (A) A glass electrode with a reference electrode

The electrode produces about 59 mV per pH unit at 25 °C.

Question 20

What principle does a gas chromatograph use for composition analysis?

  1. Separation of components in a column by different retention times, followed by detection
  2. Weighing
  3. Absorption of light only
  4. Combustion
Show answer & solution

Answer: (A) Separation of components in a column by different retention times, followed by detection

Online GCs are used in refineries and gas plants.

Question 21

What does a conductivity analyser measure in water treatment?

  1. Dissolved oxygen
  2. Temperature only
  3. Turbidity
  4. Total dissolved ionic content of water
Show answer & solution

Answer: (D) Total dissolved ionic content of water

It monitors boiler water and RO permeate quality.

Question 22

What is the accuracy of an instrument?

  1. The repeatability of readings
  2. The closeness of a measurement to the true value
  3. The smallest detectable change
  4. The range
Show answer & solution

Answer: (B) The closeness of a measurement to the true value

Precision describes repeatability.

Question 23

What is the span of an instrument with a range of 50 to 250 °C?

  1. 50 °C
  2. 200 °C
  3. 250 °C
  4. 300 °C
Show answer & solution

Answer: (B) 200 °C

Span = upper range − lower range.

Question 24

What is hysteresis in an instrument?

  1. Linear error
  2. Zero error
  3. A difference in output for the same input approached from increasing and decreasing directions
  4. Random noise
Show answer & solution

Answer: (C) A difference in output for the same input approached from increasing and decreasing directions

Friction and magnetic effects cause hysteresis.

Question 25

What is the dead band of an instrument?

  1. The full range
  2. The span
  3. The time constant
  4. The range of input change that produces no detectable output change
Show answer & solution

Answer: (D) The range of input change that produces no detectable output change

Valve stiction creates dead band.

Question 26

What does HART protocol allow?

  1. Digital communication superimposed on a 4–20 mA analogue signal
  2. Fibre optic only communication
  3. Pneumatic signalling
  4. Wireless power transmission
Show answer & solution

Answer: (A) Digital communication superimposed on a 4–20 mA analogue signal

It is used for configuration and diagnostics.

Question 27

Which fieldbus standards are used for digital communication among field devices?

  1. 4–20 mA only
  2. Foundation Fieldbus and PROFIBUS PA
  3. Morse code
  4. 3–15 psi
Show answer & solution

Answer: (B) Foundation Fieldbus and PROFIBUS PA

They carry multiple variables on one cable.

Question 28

What is calibration of an instrument?

  1. Installing the instrument
  2. Replacing the instrument
  3. Comparing its readings against a known standard and adjusting it
  4. Painting the instrument
Show answer & solution

Answer: (C) Comparing its readings against a known standard and adjusting it

Zero and span are adjusted.

Question 29

What is cold junction compensation in thermocouple circuits?

  1. Cooling the thermocouple
  2. Correcting for the temperature of the reference junction where thermocouple wires connect to the instrument
  3. Using copper wires throughout
  4. Heating the hot junction
Show answer & solution

Answer: (B) Correcting for the temperature of the reference junction where thermocouple wires connect to the instrument

Extension wires of matching alloy are used.

Question 30

Why are RTDs often preferred over thermocouples for moderate temperatures?

  1. They are more accurate and stable
  2. They measure higher temperatures
  3. They respond faster always
  4. They are cheaper always
Show answer & solution

Answer: (A) They are more accurate and stable

Thermocouples suit higher temperatures and fast response.

Question 31

What is an infrared pyrometer used for?

  1. Measuring level
  2. Measuring flow
  3. Non-contact temperature measurement of hot or moving surfaces
  4. Measuring pressure
Show answer & solution

Answer: (C) Non-contact temperature measurement of hot or moving surfaces

Emissivity must be set correctly.

Question 32

What is a Bourdon tube gauge used for?

  1. pH measurement
  2. Local pressure indication
  3. Level measurement
  4. Temperature measurement
Show answer & solution

Answer: (B) Local pressure indication

It is the most common mechanical pressure gauge.

Question 33

What is a capacitance level probe based on?

  1. Microwave reflection
  2. Hydrostatic pressure
  3. Change in capacitance as the level of material between electrodes changes
  4. Change in resistance with temperature
Show answer & solution

Answer: (C) Change in capacitance as the level of material between electrodes changes

It suits many liquids and powders.

Question 34

What is the response time of a measuring element?

  1. The range
  2. The calibration interval
  3. The accuracy
  4. The time it takes to respond to a change in the measured variable, often characterised by a time constant
Show answer & solution

Answer: (D) The time it takes to respond to a change in the measured variable, often characterised by a time constant

Sensor lags add to loop dynamics.

Question 35

Which analyser monitors oxygen in flue gas for combustion control?

  1. Zirconia oxygen analyser
  2. Turbidity meter
  3. Conductivity meter
  4. pH meter
Show answer & solution

Answer: (A) Zirconia oxygen analyser

It works at high temperature in situ.

Question 36

What is a strain gauge?

  1. A temperature sensor
  2. A sensor whose resistance changes with mechanical strain, used in load cells and pressure sensors
  3. A flow meter
  4. A level float
Show answer & solution

Answer: (B) A sensor whose resistance changes with mechanical strain, used in load cells and pressure sensors

Wheatstone bridges measure the small changes.

Question 37

What does a load cell measure?

  1. pH
  2. Level directly by radar
  3. Weight or force
  4. Temperature
Show answer & solution

Answer: (C) Weight or force

Weighing of tanks and hoppers uses load cells.

Practice these 37 questions interactively →