What is the accuracy of a measuring instrument?
Show answer & solution
Answer: (D) The closeness of a measured value to the true value
Accuracy depends on systematic and random errors.
Electrical Engineering · Measurements & Instrumentation
29 questions, each with the answer and a worked solution.
Practice interactively and track your score →What is the accuracy of a measuring instrument?
Answer: (D) The closeness of a measured value to the true value
Accuracy depends on systematic and random errors.
What is precision of a measuring instrument?
Answer: (B) The closeness of repeated measurements to each other
A precise instrument may still be inaccurate if it has a bias.
Which characteristic represents the smallest input change that an instrument can detect?
Answer: (C) Resolution
Digital meters show resolution as the value of the last digit.
What is the sensitivity of an instrument?
Answer: (A) The ratio of change in output to change in input
High sensitivity gives a large response to small input changes.
Which statistical quantity indicates how widely repeated measurements are spread?
Answer: (C) Standard deviation
Smaller standard deviation means better precision.
What is linearity of an instrument?
Answer: (B) How closely its output follows a straight-line relationship with input
Non-linearity is expressed as a percentage of full scale.
What is hysteresis in an instrument?
Answer: (A) A difference in output for the same input depending on whether the input is increasing or decreasing
Friction and magnetic effects cause hysteresis.
What is repeatability of an instrument?
Answer: (D) Its ability to give the same output for repeated applications of the same input under the same conditions
Reproducibility refers to changed conditions.
Which type of error is caused by human mistakes such as misreading a scale?
Answer: (B) Gross error
Careful procedures and repeated readings reduce gross errors.
Which errors are consistent and can be corrected by calibration?
Answer: (A) Systematic errors
Instrumental, environmental and observational biases are systematic.
What are random errors in measurement?
Answer: (C) Unpredictable variations that remain after systematic errors are removed
They are treated statistically.
What is the percentage error when a voltmeter reads 98 V for a true value of 100 V?
Answer: (B) 2%
Error = (98 − 100)/100 × 100 = −2%.
What is the loading effect of a voltmeter?
Answer: (D) The change in circuit voltage caused by the current drawn by the voltmeter
A voltmeter should have very high resistance to minimise loading.
What is calibration of an instrument?
Answer: (D) Comparing its readings with a standard and adjusting or recording corrections
Regular calibration keeps instruments accurate.
How is the limiting error of a product or quotient of measured quantities found?
Answer: (C) By adding the percentage limiting errors of the individual quantities
For example, P = VI has error %V + %I.
What is the limiting error in power calculated from voltage measured to ±1% and current to ±2%?
Answer: (A) ±3%
Percentage errors add for products.
What is a primary standard?
Answer: (D) A standard of the highest accuracy, maintained by national laboratories
Secondary and working standards are calibrated against primary standards.
What is drift in an instrument?
Answer: (B) A gradual change in reading with time while the input is constant
Temperature and ageing cause drift.
What is dead zone of an instrument?
Answer: (A) The largest range of input values for which there is no output response
Friction and backlash cause dead zones.
What is the probable error of a set of measurements?
Answer: (C) 0.6745 times the standard deviation
Half the readings lie within ± probable error of the mean.
What is the difference between static and dynamic characteristics of an instrument?
Answer: (C) Static characteristics apply to steady inputs; dynamic ones describe response to changing inputs
Dynamic characteristics include speed of response and fidelity.
What does "range" of an instrument mean?
Answer: (A) The limits between which it can measure
Span is the difference between the upper and lower limits.
Why should the reading of an analogue instrument preferably be taken in the upper part of the scale?
Answer: (B) The percentage error relative to the reading is smaller there
Accuracy is usually stated as a percentage of full scale.
What is the arithmetic mean of readings 10.2, 10.4 and 10.6 V?
Answer: (B) 10.4 V
Mean = 31.2/3 = 10.4 V.
What is parallax error?
Answer: (D) An error caused by viewing a pointer and scale from an angle
Mirror scales help avoid parallax.
Which is the SI base unit of electric current?
Answer: (A) Ampere
The volt, ohm and watt are derived units.
What is the relative error when a 0–100 V meter with ±1% full-scale accuracy reads 20 V?
Answer: (D) ±5%
±1 V error at 20 V is ±5% of the reading.
What is the main purpose of traceability in measurement?
Answer: (D) Linking measurements to national or international standards through an unbroken chain of calibrations
Calibration certificates document traceability.
What is meant by the response time of an instrument?
Answer: (B) The time taken to respond to a step change in input
Fast response is needed for dynamic measurements.