Which bridge circuit is commonly used to measure an unknown medium electrical resistance?
Show answer & solution
Answer: (D) Wheatstone bridge
It is accurate for about 1 Ω to 100 kΩ.
Electrical Engineering · Measurements & Instrumentation
28 questions, each with the answer and a worked solution.
Practice interactively and track your score →Which bridge circuit is commonly used to measure an unknown medium electrical resistance?
Answer: (D) Wheatstone bridge
It is accurate for about 1 Ω to 100 kΩ.
What is the unknown resistance S in a balanced Wheatstone bridge with P = 100 Ω, Q = 10 Ω and R = 50 Ω?
Answer: (B) 5 Ω
S = RQ/P = 50 × 10/100.
Which bridge is used to measure very low resistances below 1 Ω accurately?
Answer: (A) Kelvin double bridge
It eliminates lead and contact resistance errors.
Which bridge is commonly employed to measure an unknown capacitance and dielectric loss?
Answer: (C) Schering bridge
It is used for testing high-voltage cables and insulators.
Which bridge is used to measure inductance of medium-Q coils by comparison with a standard capacitor?
Answer: (D) Maxwell bridge
Maxwell's inductance–capacitance bridge suits coils with Q from 1 to 10.
Which bridge is preferred for measuring inductance of high-Q coils?
Answer: (C) Hay's bridge
Hay's bridge uses a series RC arm.
Which bridge measures self-inductance accurately over a wide range using a capacitor, and is a modification of Maxwell's bridge?
Answer: (D) Anderson bridge
It gives accurate results even for low-Q coils.
Which bridge is used to measure frequency in the audio range?
Answer: (A) Wien bridge
It is also used as the basis of Wien bridge oscillators.
Which simple bridge measures capacitance of a lossless capacitor by comparison with a standard capacitor?
Answer: (A) De Sauty bridge
It cannot measure dielectric loss.
What are the balance conditions of an AC bridge?
Answer: (D) Both the magnitudes and the phase angles of opposite-arm impedance products must be equal
Z₁Z₄ = Z₂Z₃ in both magnitude and angle.
Which detector is commonly used with AC bridges at audio frequencies?
Answer: (C) Headphones or an electronic null detector
Vibration galvanometers are used at power frequencies.
What is the purpose of a Wagner earth device in AC bridges?
Answer: (B) To eliminate errors due to stray capacitance to earth
It brings the detector to earth potential at balance.
What is the main advantage of a DC potentiometer for voltage measurement?
Answer: (C) It draws no current from the source at balance, giving very accurate results
It is a null-balance method.
Which method is used to measure very high resistances such as cable insulation?
Answer: (D) Loss of charge method or megger test
High resistance measurements need guard circuits to eliminate leakage.
What is a guard terminal used for in high resistance measurement?
Answer: (A) To bypass surface leakage currents away from the measuring circuit
Guarding improves accuracy in insulation testing.
Which bridge is a modification of the Wheatstone bridge for comparing two nearly equal resistances?
Answer: (B) Carey Foster bridge
It uses a slide wire.
What is the effect of using a higher bridge supply voltage on bridge sensitivity?
Answer: (B) Sensitivity increases, but heating of resistors must be limited
Power dissipation limits the supply voltage.
Why is the Schering bridge important for high-voltage insulation testing?
Answer: (D) It measures capacitance and loss tangent of insulation at high voltage safely
The high-voltage arms are placed away from the operator.
Which bridge uses two potentiometer-like arms to measure resistance of a few milliohms in shunts and busbars?
Answer: (C) Kelvin double bridge
Four-terminal connections remove lead effects.
What is the principle of a null-balance measurement?
Answer: (A) The unknown is adjusted against a known quantity until a detector shows zero
Null methods are very accurate because the detector need not be calibrated.
What is the condition for balance of Maxwell's inductance–capacitance bridge?
Answer: (C) Lx = R2R3C1 and Rx = R2R3/R1
The balance is independent of frequency.
Why is a slide-wire potentiometer standardised before use?
Answer: (B) To set the current so that the wire's voltage per unit length matches a standard cell
A Weston standard cell or reference provides the standard voltage.
What is a crossed-coil ohmmeter (megger) independent of?
Answer: (D) Variations in the generator voltage
The deflection depends on the ratio of currents in the two coils.
Which bridge measures mutual inductance between two coils?
Answer: (B) Heaviside or Campbell bridge
Mutual inductance can also be measured with Maxwell's methods.
What is the main source of error in measuring low resistances with a Wheatstone bridge?
Answer: (A) Lead and contact resistances
The Kelvin bridge eliminates these errors.
What is the advantage of an AC potentiometer?
Answer: (C) It can measure AC voltages in both magnitude and phase
Polar and coordinate types exist.
What type of supply is used for the Schering bridge in insulation testing?
Answer: (B) High-voltage AC at power frequency
It measures capacitance and tan δ under service-like stress.
What is the purpose of a vibration galvanometer?
Answer: (C) A detector for AC bridges at power frequencies
It resonates at the supply frequency.