Which instrument displays an electrical waveform against time on a screen?
Show answer & solution
Answer: (A) Oscilloscope
It shows amplitude, frequency, phase and distortion.
Electrical Engineering · Measurements & Instrumentation
31 questions, each with the answer and a worked solution.
Practice interactively and track your score →Which instrument displays an electrical waveform against time on a screen?
Answer: (A) Oscilloscope
It shows amplitude, frequency, phase and distortion.
Which instrument displays the amplitude of a signal against frequency?
Answer: (B) Spectrum analyzer
It is used for analysing harmonics and RF signals.
What are Lissajous patterns on an oscilloscope used for?
Answer: (A) Comparing frequency and phase of two signals
One signal drives the X plates and the other the Y plates.
What is the frequency ratio shown by a Lissajous figure with two horizontal tangencies and one vertical tangency?
Answer: (C) 2:1 (Y to X)
The ratio of tangencies gives the frequency ratio.
Which type of analogue-to-digital converter is the fastest?
Answer: (D) Flash (parallel) ADC
It uses many comparators working simultaneously.
Which type of ADC is commonly used in digital multimeters because of its noise rejection?
Answer: (B) Dual-slope integrating ADC
Integration over a power cycle rejects mains noise.
Which ADC type offers a good balance of speed and resolution and is common in microcontrollers?
Answer: (C) Successive approximation ADC
It tests one bit at a time from the most significant bit.
What is the resolution of an 8-bit ADC with a 5 V reference?
Answer: (C) About 19.5 mV
Resolution = 5/2⁸ = 5/256 ≈ 19.5 mV.
What is the maximum reading of a 3½-digit display?
Answer: (B) 1,999
The half digit can be only 0 or 1.
What does the Nyquist criterion require when sampling a signal in a digital oscilloscope?
Answer: (D) A sampling rate of at least twice the highest frequency in the signal
Undersampling causes aliasing.
What is the function of a 10:1 oscilloscope probe?
Answer: (A) To reduce loading on the circuit and extend voltage range by attenuating the signal
The probe must be compensated using the scope's calibration signal.
Which instrument counts cycles of a signal over a precise time interval to display frequency?
Answer: (A) Frequency counter
It uses a crystal time base.
What is a function generator used for?
Answer: (B) Producing test signals such as sine, square and triangle waves
It is used for testing amplifiers and filters.
What is an LCR meter?
Answer: (D) An instrument that measures inductance, capacitance and resistance
It uses AC test signals at selectable frequencies.
What does a digital multimeter's "true RMS" feature mean?
Answer: (A) It measures the correct RMS value of non-sinusoidal waveforms
Average-responding meters err on distorted waveforms.
What is the main part of an analogue oscilloscope that produces the display?
Answer: (D) Cathode ray tube with electron gun and deflection plates
Modern digital oscilloscopes use flat-panel displays.
What is a data logger?
Answer: (C) An instrument that records measurements automatically over time
Data loggers monitor temperature, voltage and energy.
What is a digital-to-analogue converter (DAC) used for?
Answer: (B) Converting digital codes into proportional analogue voltages or currents
R-2R ladders are a common DAC design.
What is aliasing in digital sampling?
Answer: (D) False lower-frequency components appearing when a signal is sampled too slowly
Anti-aliasing filters remove frequencies above half the sampling rate.
What is the main advantage of digital instruments over analogue instruments?
Answer: (C) Higher accuracy, no parallax error and easy data storage
Digital readings can be logged and transmitted.
What does the triggering control of an oscilloscope do?
Answer: (B) It synchronises the sweep with the signal to give a stable display
Edge triggering is the most common mode.
How many quantisation levels does a 10-bit ADC have?
Answer: (D) 1,024
2¹⁰ = 1,024.
What is the function of the timebase in an oscilloscope?
Answer: (C) To sweep the trace horizontally at a known rate
Timebase settings are given in time per division.
What is the period of a waveform that occupies 4 divisions on an oscilloscope set at 5 ms/div?
Answer: (C) 20 ms
T = 4 × 5 ms; frequency = 50 Hz.
What is the peak-to-peak voltage of a waveform occupying 6 vertical divisions at 2 V/div?
Answer: (C) 12 V
Vpp = 6 × 2 V.
What is the main advantage of a digital storage oscilloscope (DSO)?
Answer: (D) It can capture, store and analyse single events and waveforms
DSOs can measure automatically and export data.
What is quantisation error in an ADC?
Answer: (D) The difference between the actual analogue value and the nearest digital level
It is at most half the resolution step.
What is the resolution of a 12-bit ADC with a 4.096 V reference?
Answer: (B) 1 mV
4.096/4096 = 0.001 V.
What is a remote terminal unit (RTU) used for?
Answer: (A) Collecting field data and sending it to a SCADA master station
RTUs are used in grid stations and pipelines.
What is the purpose of the bandwidth specification of an oscilloscope?
Answer: (B) It indicates the highest frequency the scope can measure with small amplitude error
A scope's bandwidth should be well above the signal frequency.
What is the main use of a power analyser?
Answer: (A) Measuring power, power factor, harmonics and efficiency of electrical equipment
Power analysers are used for testing drives and inverters.