What does the Souders–Brown equation give in column and separator design?
Show answer & solution
Answer: (D) The maximum allowable vapour velocity u = K√((ρL − ρV)/ρV)
K depends on tray spacing or demister type.
Chemical Engineering · Process Equipment & Plant Design
42 questions, each with the answer and a worked solution.
Practice interactively and track your score →What does the Souders–Brown equation give in column and separator design?
Answer: (D) The maximum allowable vapour velocity u = K√((ρL − ρV)/ρV)
K depends on tray spacing or demister type.
How is the diameter of a distillation column found?
Answer: (B) From the vapour flow rate and an allowable vapour velocity below flooding
Design is often at 70–85% of flooding.
What is a typical tray spacing in distillation columns?
Answer: (B) About 0.45 to 0.6 m
Larger spacing allows higher vapour velocity.
How many actual trays are needed if 15 theoretical stages (excluding reboiler) are required and tray efficiency is 60%?
Answer: (C) 25
15/0.6.
What is the approximate height of a column with 25 trays at 0.6 m spacing, plus 3 m for top and bottom space?
Answer: (C) 18 m
25 × 0.6 + 3.
What is the typical liquid residence time used for sizing reflux drums and separators?
Answer: (C) About 5 to 10 minutes of hold-up
Hold-up absorbs upsets and gives time for operators to respond.
What is a demister (mist eliminator) used for in separators?
Answer: (A) Removing fine liquid droplets from the gas leaving a separator
Wire mesh pads are common.
What is the main difference between a horizontal and a vertical separator?
Answer: (D) Horizontal separators suit high liquid loads; vertical ones suit high gas-to-liquid ratios and small plot area
Three-phase separation favours horizontal vessels.
What is a three-phase separator used for in oil and gas production?
Answer: (D) Separating gas, oil and water
Weirs and boots collect water.
What standard tube outside diameters are common in shell and tube exchangers?
Answer: (C) 19.05 mm (3/4 inch) and 25.4 mm (1 inch)
Standard tube lengths are 8, 12, 16 and 20 ft.
What is a common overdesign factor added to calculated equipment capacity?
Answer: (B) About 10 to 20%
It covers uncertainties in data and future capacity.
What is the heat transfer area per tube for a 25.4 mm OD tube 6 m long?
Answer: (B) About 0.48 m²
A = πDL = π × 0.0254 × 6.
What does pump selection mainly depend on?
Answer: (A) Flow rate, head, fluid properties and NPSH available
Centrifugal pumps are chosen for most clean liquid duties.
Which standard covers centrifugal pumps for petroleum, petrochemical and gas industries?
Answer: (D) API 610
It specifies heavy-duty construction.
What is the hydraulic power of a pump delivering 50 m³/h against 40 m head of water?
Answer: (C) About 5.45 kW
P = ρgQH = 1,000 × 9.81 × (50/3,600) × 40.
How is the volume of a reactor sized from production rate?
Answer: (A) From residence time needed for the required conversion and the volumetric throughput
V = τ × volumetric flow for continuous reactors.
What is the purpose of a surge (buffer) tank between process units?
Answer: (D) To absorb flow fluctuations and decouple upstream and downstream units
Averaging level control uses its capacity.
What is the working volume of a storage tank usually taken as?
Answer: (C) About 80–90% of the total volume, leaving space for expansion and vapour
Safe filling limits prevent overflow.
What is the purpose of a flare system?
Answer: (A) Safe disposal of relief and vent gases by combustion
Flare design follows API 521.
What determines the height and position of a flare stack?
Answer: (B) Allowable radiant heat intensity at ground level and on personnel
API 521 gives radiation limits.
What does a knock-out drum before a flare do?
Answer: (A) Removes liquid from relief gases before they reach the flare
Liquid carry-over can cause burning rain.
What is the typical approach temperature in cooling water exchangers?
Answer: (B) About 5–10 °C
Small approaches require large areas.
What is the typical design cooling water supply temperature in hot climates such as in Pakistan?
Answer: (C) About 32–35 °C
It depends on the ambient wet bulb temperature at the cooling tower.
What does packing height for an absorber equal?
Answer: (D) HTU × NTU (or HETP × number of stages)
Additional height is added for distributors and supports.
What is the maximum allowable vapour velocity in a separator if K = 0.1 m/s, ρL = 800 kg/m³ and ρV = 8 kg/m³?
Answer: (B) About 0.995 m/s
u = 0.1 × √(792/8) = 0.1 × 9.95.
What is the cross-sectional area needed for 2 m³/s of vapour at an allowable velocity of 1 m/s?
Answer: (C) 2 m²
A = Q/u.
What is the column diameter for a required cross-sectional area of 3.14 m²?
Answer: (B) 2 m
D = √(4A/π).
What is the downcomer area of a tray typically as a fraction of column area?
Answer: (B) About 10–15%
It must handle liquid flow without backing up.
What is the typical weir height on sieve trays in atmospheric columns?
Answer: (C) About 40–90 mm
Lower weirs are used in vacuum service.
What is the typical hole area of a sieve tray as a fraction of active area?
Answer: (B) About 5–15%
Hole diameters are usually 3–12 mm.
What is turndown ratio for a tray column?
Answer: (D) The ratio of maximum to minimum vapour rates for satisfactory operation
Valve trays offer better turndown than sieve trays.
Why are packed columns preferred to tray columns for small diameters below about 0.6 m?
Answer: (A) Trays are difficult to install and maintain in small columns, and packing is cheaper
Packed columns also suit corrosive and foaming service.
Why are tray columns preferred when liquid contains solids or tends to foul?
Answer: (C) Trays are easier to clean and less prone to plugging than random packing
Large-diameter columns also often use trays.
What is the typical pressure drop per tray in atmospheric distillation?
Answer: (B) About 0.5–1 kPa
Vacuum columns need low-pressure-drop internals.
What is the main criterion for choosing tube-side versus shell-side for cooling water?
Answer: (A) Cooling water usually goes in tubes for easy cleaning and better velocity control
Fouling fluids go where cleaning is easiest.
What is a typical tube-side velocity for liquids in heat exchangers?
Answer: (B) About 1–3 m/s
Higher velocities reduce fouling but raise pressure drop.
How many tubes 6 m long and 25.4 mm OD are needed for 48 m² of heat transfer area?
Answer: (C) About 100
Each tube has about 0.48 m².
What is the typical allowable pressure drop for liquids in a heat exchanger?
Answer: (D) About 35–70 kPa
Gas-side allowances are lower.
What is the purpose of a vortex breaker in a vessel outlet nozzle?
Answer: (A) To prevent vortex formation that draws gas into the pump suction
It protects pumps from cavitation and gas entrainment.
What is the typical economic L/D ratio for a horizontal separator?
Answer: (C) About 3 to 5
Very long vessels are costly to support.
What is the typical holding time used for sizing a feed surge drum?
Answer: (D) About 10–20 minutes of feed flow
It allows downstream units to ride through upsets.
What is the typical minimum NPSH margin recommended between NPSH available and NPSH required for process pumps?
Answer: (B) About 0.6–1 m or 10–35%, depending on the service
A margin protects against cavitation from transient conditions.