Engineering, Management, Agriculture and Veterinary MCQs are now live. FPSC, PPSC, EPE, IELTS & GRE coming soon.

Renewable Energy: Solar Radiation and PV Cells

Electrical Engineering · Renewable Energy

28 questions, each with the answer and a worked solution.

Practice interactively and track your score →
Question 1

What is the approximate value of the solar constant outside the earth's atmosphere?

  1. About 13.6 W/m²
  2. About 100 W/m²
  3. About 1,000 kW/m²
  4. About 1,361 W/m²
Show answer & solution

Answer: (D) About 1,361 W/m²

At the earth's surface, peak irradiance is about 1,000 W/m².

Question 2

What are the standard test conditions (STC) used to rate PV modules?

  1. 500 W/m² and 50 °C
  2. 800 W/m² and 45 °C ambient only
  3. 1,000 W/m² irradiance, 25 °C cell temperature and air mass 1.5
  4. 1,361 W/m² and 0 °C
Show answer & solution

Answer: (C) 1,000 W/m² irradiance, 25 °C cell temperature and air mass 1.5

Module nameplate power is given at STC.

Question 3

On which effect does a solar cell work?

  1. Photovoltaic effect
  2. Piezoelectric effect
  3. Hall effect
  4. Seebeck effect
Show answer & solution

Answer: (A) Photovoltaic effect

Light creates electron–hole pairs that are separated by the PN junction.

Question 4

What is the typical open-circuit voltage of a single crystalline silicon solar cell?

  1. About 0.06 V
  2. About 0.6 V
  3. About 6 V
  4. About 12 V
Show answer & solution

Answer: (B) About 0.6 V

Cells are connected in series to build module voltage.

Question 5

Which type of silicon solar module generally has the highest efficiency?

  1. Cadmium-free organic film
  2. Monocrystalline
  3. Amorphous thin film
  4. Polycrystalline
Show answer & solution

Answer: (B) Monocrystalline

Commercial monocrystalline modules exceed 20% efficiency.

Question 6

How is the fill factor of a solar cell defined?

  1. Open-circuit voltage divided by short-circuit current
  2. Short-circuit current divided by area
  3. Maximum power divided by the product of open-circuit voltage and short-circuit current
  4. Efficiency multiplied by area
Show answer & solution

Answer: (C) Maximum power divided by the product of open-circuit voltage and short-circuit current

A higher fill factor means a squarer I–V curve.

Question 7

What is the fill factor of a module with Pmax = 300 W, Voc = 40 V and Isc = 9.5 A?

  1. About 0.65
  2. About 0.79
  3. About 0.95
  4. About 1.26
Show answer & solution

Answer: (B) About 0.79

FF = 300/(40 × 9.5) = 300/380.

Question 8

What is the efficiency of a 300 W module with an area of 1.6 m² at 1,000 W/m²?

  1. About 5.3%
  2. About 12%
  3. About 18.8%
  4. About 30%
Show answer & solution

Answer: (C) About 18.8%

η = 300/(1,000 × 1.6).

Question 9

How does rising cell temperature affect PV module output?

  1. There is no effect
  2. Power increases
  3. Current falls to zero
  4. Voltage and power decrease
Show answer & solution

Answer: (D) Voltage and power decrease

Power falls by roughly 0.3–0.5% per °C above 25 °C.

Question 10

How is the short-circuit current of a solar cell related to irradiance?

  1. It is approximately proportional to irradiance
  2. It is independent of irradiance
  3. It depends only on temperature
  4. It is inversely proportional
Show answer & solution

Answer: (A) It is approximately proportional to irradiance

Voltage changes much less with irradiance.

Question 11

Which quantity primarily increases when identical photovoltaic modules are connected in parallel?

  1. Operating frequency
  2. Open-circuit voltage
  3. Cell temperature
  4. Output current
Show answer & solution

Answer: (D) Output current

Series connection increases voltage.

Question 12

What is the purpose of bypass diodes in PV modules?

  1. To let current bypass shaded cells and prevent hot spots
  2. To convert DC to AC
  3. To increase voltage
  4. To block current at night
Show answer & solution

Answer: (A) To let current bypass shaded cells and prevent hot spots

Shaded cells can otherwise act as loads and overheat.

Question 13

What is a hot spot in a PV module?

  1. A sunny area
  2. A local overheating of a shaded or damaged cell forced into reverse bias
  3. A cable joint
  4. A cooling fault in the inverter
Show answer & solution

Answer: (B) A local overheating of a shaded or damaged cell forced into reverse bias

Hot spots can permanently damage modules.

Question 14

What are "peak sun hours"?

  1. The hours between sunrise and sunset
  2. The hours of cloud cover
  3. The equivalent number of hours per day of 1,000 W/m² irradiance giving the same daily energy
  4. The hours of maximum temperature
Show answer & solution

Answer: (C) The equivalent number of hours per day of 1,000 W/m² irradiance giving the same daily energy

5 peak sun hours means 5 kWh/m² per day.

Question 15

What is the approximate average daily solar irradiation in most of Pakistan?

  1. About 0.5 kWh/m² per day
  2. About 5 to 7 kWh/m² per day
  3. About 20 kWh/m² per day
  4. About 50 kWh/m² per day
Show answer & solution

Answer: (B) About 5 to 7 kWh/m² per day

Balochistan and southern Punjab and Sindh receive some of the highest values.

Question 16

What is a good rule for the fixed tilt angle of PV modules in Pakistan for maximum annual yield?

  1. Approximately equal to the site's latitude, facing south
  2. 90° facing west
  3. Horizontal facing north
  4. Vertical facing east
Show answer & solution

Answer: (A) Approximately equal to the site's latitude, facing south

Pakistan lies between about 24° and 37° N.

Question 17

What do the points Isc, Voc and MPP on a PV I–V curve represent?

  1. Battery limits
  2. Inverter settings
  3. Cable ratings
  4. Short-circuit current, open-circuit voltage and maximum power point
Show answer & solution

Answer: (D) Short-circuit current, open-circuit voltage and maximum power point

The module delivers maximum power at the MPP.

Question 18

What is a bifacial PV module?

  1. A module that collects light on both its front and rear surfaces
  2. A thermal collector
  3. A module that tracks the sun
  4. A module with two junction boxes
Show answer & solution

Answer: (A) A module that collects light on both its front and rear surfaces

Rear-side gain depends on ground reflectivity.

Question 19

What is air mass (AM) in solar energy?

  1. The weight of air on a module
  2. The humidity
  3. The wind speed
  4. The relative path length of sunlight through the atmosphere
Show answer & solution

Answer: (D) The relative path length of sunlight through the atmosphere

AM 1.5 corresponds to the sun about 48° from the zenith.

Question 20

Which semiconductor material is used in most commercial solar cells?

  1. Germanium
  2. Carbon
  3. Silicon
  4. Copper
Show answer & solution

Answer: (C) Silicon

Thin-film technologies use materials such as CdTe and CIGS.

Question 21

What is direct normal irradiance (DNI)?

  1. Radiation scattered by the sky
  2. Reflected radiation from the ground
  3. Infrared radiation only
  4. Solar radiation received directly from the sun on a surface perpendicular to the rays
Show answer & solution

Answer: (D) Solar radiation received directly from the sun on a surface perpendicular to the rays

Concentrating solar plants depend on DNI.

Question 22

What is the effect of dust accumulation on PV modules in dry areas of Pakistan?

  1. It reduces output significantly unless modules are cleaned regularly
  2. It increases output
  3. It has no effect
  4. It cools the modules
Show answer & solution

Answer: (A) It reduces output significantly unless modules are cleaned regularly

Soiling losses can exceed 10% between cleanings.

Question 23

What is the main benefit of single-axis solar trackers?

  1. They cool modules
  2. They follow the sun's daily movement, increasing energy yield
  3. They reduce yield
  4. They store energy
Show answer & solution

Answer: (B) They follow the sun's daily movement, increasing energy yield

Yield can rise by 15–25% compared with fixed tilt.

Question 24

Why does a PV module's power output fall in very hot summer months in Pakistan despite strong sunlight?

  1. Irradiance is zero
  2. The modules stop working above 30 °C
  3. High cell temperatures reduce voltage and efficiency
  4. Inverters switch off
Show answer & solution

Answer: (C) High cell temperatures reduce voltage and efficiency

Ventilation behind modules helps reduce temperature.

Question 25

How does PV module current change on a cloudy day compared with full sunshine?

  1. It falls roughly in proportion to irradiance
  2. It stays the same
  3. It becomes negative
  4. It rises
Show answer & solution

Answer: (A) It falls roughly in proportion to irradiance

Voltage falls only slightly.

Question 26

What is the main advantage of thin-film PV modules?

  1. Higher efficiency than all silicon modules
  2. No degradation
  3. Better performance at high temperature and low light with lower material use
  4. Lower area needed
Show answer & solution

Answer: (C) Better performance at high temperature and low light with lower material use

They need more area for the same power.

Question 27

What is PV module degradation?

  1. Temperature rise only
  2. Cleaning of the module
  3. Increase of power with age
  4. The gradual loss of output power over the module's life
Show answer & solution

Answer: (D) The gradual loss of output power over the module's life

Typical warranties guarantee about 80–85% power after 25 years.

Question 28

What is the main function of the anti-reflection coating on solar cells?

  1. To insulate the cell
  2. To make cells heavier
  3. To reduce reflection and increase absorbed light
  4. To increase reflection
Show answer & solution

Answer: (C) To reduce reflection and increase absorbed light

It gives cells their dark blue or black appearance.

Practice these 28 questions interactively →