Engineering, Management, Agriculture and Veterinary MCQs are now live. FPSC, PPSC, EPE, IELTS & GRE coming soon.
Public Health Engineering: Wastewater Characteristics, Sewerage and House Drainage
Civil Engineering · Public Health Engineering
50 questions, each with the answer and a worked solution.
Practice interactively and track your score →Question 1
Crown corrosion of concrete sewers is mainly caused by
- bacteria converting hydrogen sulphide into sulphuric acid on the exposed pipe crown
- rain water falling on the road surface above the sewer and seeping through the cover
- abrasion by grit carried at the pipe invert
- freezing of water inside the pipe wall
Show answer & solution
Answer: (A) bacteria converting hydrogen sulphide into sulphuric acid on the exposed pipe crown
Anaerobic sulphate reduction gives H2S; Thiobacillus oxidizes it to H2SO4, attacking the concrete crown.
Question 2
Vent pipes in a house drainage system mainly serve to
- admit air, keep atmospheric pressure and release gas above the roof
- supply potable water to fixtures located on the upper floors through the stack
- increase the discharge of sewage into the public sewer by creating suction
- filter solids from the sewage before it leaves the building through the trap
Show answer & solution
Answer: (A) admit air, keep atmospheric pressure and release gas above the roof
Vents prevent siphonage and back-pressure that could break trap seals and carry gases above the roof.
Question 3
The minimum (self-cleansing) velocity in sewer design is intended to
- prevent solids from settling and accumulating in the sewer
- prevent sewage from becoming septic by slowing it down
- maximize the detention time of sewage in the pipe
- prevent scouring of the sewer pipe material by abrasive grit carried in the sewage
Show answer & solution
Answer: (A) prevent solids from settling and accumulating in the sewer
A minimum velocity of about 0.6-0.9 m/s (commonly 0.75 m/s) at design flow keeps solids moving.
Question 4
Biochemical oxygen demand (BOD) is the
- oxygen consumed by microorganisms decomposing organic matter over a set period (usually 5 days at 20°C)
- amount of dissolved oxygen present in the sample at saturation for the given temperature
- oxygen needed to oxidize all organic and inorganic matter chemically using a strong oxidant
- total oxygen consumed by algae in the sample through photosynthesis over five days at 20°C
Show answer & solution
Answer: (A) oxygen consumed by microorganisms decomposing organic matter over a set period (usually 5 days at 20°C)
BOD5 at 20°C measures biodegradable organic load; strong domestic sewage has BOD5 of about 250-400 mg/L.
Question 5
Hydrogen sulphide corrosion and odour in sewers can be controlled by
- keeping self-cleansing velocity, ventilation, and chemical dosing or corrosion-resistant linings
- lowering velocity to the minimum possible and providing no ventilation, to limit gas release
- sealing every manhole airtight and providing no ventilation, so that gases cannot escape
- increasing the organic load and detention time of the sewage in the sewers
Show answer & solution
Answer: (A) keeping self-cleansing velocity, ventilation, and chemical dosing or corrosion-resistant linings
Measures: avoid septicity, aerate, dose chlorine/iron salts/nitrate, and use PVC or lined pipes.
Question 6
Ventilation of sewers is provided to
- prevent air from reaching the sewage
- prevent build-up of toxic or explosive gases and reduce odour and corrosion
- apply only to storm water drains, not sanitary sewers
- increase the build-up of hydrogen sulphide so that it is diluted by sewage at the invert
Show answer & solution
Answer: (B) prevent build-up of toxic or explosive gases and reduce odour and corrosion
Ventilation through manhole covers and stacks dilutes H2S and methane and keeps conditions aerobic.
Question 7
In a separate sewerage system,
- sanitary sewage and storm water are carried in two independent sewer networks
- both are carried together in one network, with an overflow weir provided for storms
- only storm water is collected in pipes
- sanitary sewage is discharged to open drains while storm water is piped
Show answer & solution
Answer: (A) sanitary sewage and storm water are carried in two independent sewer networks
Separate system = separate sanitary and storm sewers.
Question 8
Manholes in a sewer system are provided mainly for
- metering the volume of sewage
- disinfection of sewage with chlorine
- inspection, cleaning and maintenance access to the sewer line
- partial treatment of the sewage by sedimentation of heavy solids in the chamber
Show answer & solution
Answer: (C) inspection, cleaning and maintenance access to the sewer line
Manholes are provided at changes of direction, gradient, size and junctions, and at intervals along straight lengths.
Question 9
Compared with domestic sewage, industrial wastewater
- varies widely with the industry and may need pre-treatment before discharge to a sewer
- is always weaker than domestic sewage and can be discharged directly to the sewer
- consists mainly of human excreta, soaps and detergents and seldom contains toxic chemicals
- has the same composition as domestic sewage regardless of the type of industry served
Show answer & solution
Answer: (A) varies widely with the industry and may need pre-treatment before discharge to a sewer
Industrial effluents (textile, tannery, sugar etc.) differ in BOD, pH, toxicity and temperature, so pre-treatment is often required.
Question 10
Lamp holes in a sewer system are
- chambers for dropping sewage to a lower level
- vent shafts for releasing sewer gases
- large chambers that workers descend into for cleaning and for repairing the sewer line
- small openings used to lower a lamp for inspection, too small for a person to enter
Show answer & solution
Answer: (D) small openings used to lower a lamp for inspection, too small for a person to enter
A lamp hole is a vertical pipe from sewer crown to the surface for lamp-and-mirror inspection.
Question 11
Inverted siphons need careful velocity control mainly because
- the siphon is open to the atmosphere and cannot hold pressure
- solids settle easily in the depressed full-flowing section, which is hard to clean
- the siphon is self-cleansing at any velocity
- velocity has no effect on deposition in the siphon, as the full pipe flow carries all solids
Show answer & solution
Answer: (B) solids settle easily in the depressed full-flowing section, which is hard to clean
A velocity of about 1 m/s or more (often multiple barrels) is provided; siphons are difficult to access.
Question 12
A sewage pumping (lift) station is needed mainly where
- the flow is too small to carry any solids
- the entire area has a uniform downward gradient toward the treatment plant or outfall
- the ground does not allow sewage to flow by gravity to the plant or outfall
- the sewer carries only storm water
Show answer & solution
Answer: (C) the ground does not allow sewage to flow by gravity to the plant or outfall
Pumping lifts sewage from low-lying areas or deep sewers to a higher level.
Question 13
During a heavy storm, a combined sewer system may experience
- a reduction in sewer velocity below its dry-weather value
- no change in flow, because the sewers have a fixed capacity regardless of storm intensity
- a drop in pollutant load to the receiving water because storm flow is fully intercepted and treated
- combined sewer overflow, where excess flow is discharged untreated or partly treated to a water body
Show answer & solution
Answer: (D) combined sewer overflow, where excess flow is discharged untreated or partly treated to a water body
When flow exceeds sewer or plant capacity, overflow structures (storm overflows) spill diluted sewage to receiving waters.
Question 14
Low-flush and dual-flush cisterns are intended mainly to
- use more water per flush for better cleaning in normal practice
- prevent backflow into the supply line
- improve odour removal in the sewer line
- use less water per flush and so conserve water
Show answer & solution
Answer: (D) use less water per flush and so conserve water
Dual-flush cisterns provide a small flush (about 3–4 litres) and a full flush (about 6 litres), saving water.
Question 15
In a combined sewerage system,
- sanitary sewage and storm water are carried together in a single sewer network
- they are carried in two independent networks, one for sewage and one for storm runoff
- only storm water is carried in the sewers
- only sanitary sewage is carried, with storm water in open drains
Show answer & solution
Answer: (A) sanitary sewage and storm water are carried together in a single sewer network
Combined system = one sewer carries both sewage and storm runoff.
Question 16
Why must the design of a sewer system consider hydraulics, structural strength and maintenance together?
- The pipe size decides everything, since velocity, material and access can be added later
- Maintenance matters only for water supply pipes, because sewers are flushed by the flow itself
- A sewer must stay self-cleansing, structurally sound and accessible over its design life
- Once buried, a sewer needs no further consideration of velocity, material or joints
Show answer & solution
Answer: (C) A sewer must stay self-cleansing, structurally sound and accessible over its design life
Velocity, material, joints and appurtenances jointly determine long-term performance.
Question 17
Water closets are commonly of which two types?
- Flat-pan type and cylindrical-pan type only
- Siphonic cistern type and gravity cistern type only
- Squatting (Asian) pan type and pedestal type
- Single-flush type and dual-flush type only
Show answer & solution
Answer: (C) Squatting (Asian) pan type and pedestal type
WCs are available as squatting pans and pedestal seats, chosen by custom and building use.
Question 18
Proper design and installation of internal sanitary plumbing in a building is important mainly because it
- is required only for large public and commercial buildings
- ensures safe water supply and hygienic wastewater removal
- removes the need for any municipal sewerage system in the area
- affects only the appearance and finish of the building
Show answer & solution
Answer: (B) ensures safe water supply and hygienic wastewater removal
Good plumbing protects occupants and the wider environment from contamination and disease.
Question 19
Why is characterization (analysis) of wastewater the first step in designing wastewater management?
- It replaces the need for treatment processes
- It has no bearing on process selection or sizing
- It is only needed for research laboratories and has no bearing on process selection or sizing
- It supplies the flow and pollutant data on which sewer and treatment design are based
Show answer & solution
Answer: (D) It supplies the flow and pollutant data on which sewer and treatment design are based
BOD, SS, nutrients and flow variation determine the selection and sizing of treatment units.
Question 20
Manning's formula for a sewer relates flow capacity to
- the pipe colour and age only, with no reference to its slope or hydraulic radius
- the slope, size/shape (hydraulic radius) and roughness coefficient n of the pipe
- the population served only
- water temperature and barometric pressure
Show answer & solution
Answer: (B) the slope, size/shape (hydraulic radius) and roughness coefficient n of the pipe
V = (1/n)·R^(2/3)·S^(1/2); n ≈ 0.013 for concrete or clay sewers.
Question 21
Domestic (sanitary) sewage is wastewater generated mainly from
- factory process operations, cooling systems and other industrial manufacturing activities
- residential, commercial and institutional buildings through bathing, toilets, cooking and laundry
- rainfall runoff from roads, roofs and paved areas, collected through gullies and street inlets
- irrigation return flows and drainage from farmland, carrying fertilisers and soil to the nearest drain
Show answer & solution
Answer: (B) residential, commercial and institutional buildings through bathing, toilets, cooking and laundry
Domestic sewage comes from human activities in buildings; industrial and storm flows are separate categories.
Question 22
Nitrogen and phosphorus in treated sewage discharged to a water body mainly cause
- rapid disinfection of the receiving water, as the nutrients are toxic to bacteria
- eutrophication, with excessive algal growth and later oxygen depletion
- increase in the water's hardness only
- increase in dissolved oxygen without any ecological effect
Show answer & solution
Answer: (B) eutrophication, with excessive algal growth and later oxygen depletion
Nutrients stimulate algae and aquatic weeds; their decay depletes dissolved oxygen.
Question 23
Chemical oxygen demand (COD) is the
- oxygen consumed by bacteria alone over five days at 20°C in a sealed incubation bottle
- total solids remaining after evaporation of the sample at 103°C and weighed in a crucible
- dissolved oxygen remaining in the sample after incubation for a period of five days in the dark
- oxygen needed to chemically oxidize biodegradable and non-biodegradable matter with a strong oxidant such as dichromate
Show answer & solution
Answer: (D) oxygen needed to chemically oxidize biodegradable and non-biodegradable matter with a strong oxidant such as dichromate
COD uses K2Cr2O7 in acid; it takes only a few hours.
Question 24
Pathogens in untreated sewage are a major concern because they
- cause waterborne diseases such as cholera, typhoid and hepatitis when sewage contacts people
- are destroyed completely in septic tanks, so the effluent is safe for direct discharge
- are present only in industrial wastewater and are absent from ordinary domestic sewage
- are harmless to humans but can harm fish and other aquatic life in the receiving stream
Show answer & solution
Answer: (A) cause waterborne diseases such as cholera, typhoid and hepatitis when sewage contacts people
Sewage carries enteric bacteria, viruses, protozoa and helminths; treatment and safe disposal break the transmission route.
Question 25
Which factors must be considered in sewerage planning for a town?
- only the water supply source and the rainfall pattern of the area, as the rest follows from them
- only the colour and brand of the pipes, as everything else is fixed by the standards
- only the size of the treatment plant and the cost of land for the works
- topography, population growth and distribution, and the choice of separate or combined system
Show answer & solution
Answer: (D) topography, population growth and distribution, and the choice of separate or combined system
Layout, gradients, pumping needs, design period and system type depend on terrain and population.
Question 26
Pre-treatment requirements for industries discharging into municipal sewers are intended mainly to
- apply only to domestic households
- remove the need for any municipal treatment plant, since industries treat their own waste fully
- reduce the cost of water supply to the industry
- prevent damage to sewers, upset of biological treatment, and hazards to workers
Show answer & solution
Answer: (D) prevent damage to sewers, upset of biological treatment, and hazards to workers
Limits on pH, toxic metals, oil, temperature and BOD protect the sewers and treatment plant.
Question 27
An inverted siphon in a sewer line is a
- raised section that passes above the obstacle and runs part full under atmospheric pressure
- vertical drop used to change levels inside a manhole
- pumped section lifting sewage over a rise
- depressed section that dips below an obstacle and runs full under pressure
Show answer & solution
Answer: (D) depressed section that dips below an obstacle and runs full under pressure
Inverted siphons carry sewage under rivers, railways or depressions; they flow full by pressure, not gravity alone.
Question 28
Quantity of sewage from a community is usually estimated from
- the number of houses only, at 1000 litres per house
- a fixed value of 25 litres per head per day for every town
- the water supplied per capita, taking about 80% of it as reaching the sewers
- the rainfall depth over the catchment alone, using the rational method for the storm
Show answer & solution
Answer: (C) the water supplied per capita, taking about 80% of it as reaching the sewers
Sewage flow is taken as roughly 70-80% of water consumption (rest lost in use, lawn watering, leakage).
Question 29
Infiltration into a sanitary sewer refers to
- house sewage that consumers discharge into the sewer through their connections
- groundwater entering through defective joints, cracks and manholes
- industrial effluent entering through trade connections
- storm water connected deliberately through roof drains
Show answer & solution
Answer: (B) groundwater entering through defective joints, cracks and manholes
Infiltration is extraneous groundwater entering via leaks; it increases hydraulic load and is allowed for in design.
Question 30
A drop manhole is provided where
- sewage must be lifted by pumping to a sewer at a higher level
- the sewer must cross beneath a river or railway embankment by an inverted siphon
- two sewers of equal invert level meet at a junction and a smooth transition is needed
- an incoming sewer is much higher than the outgoing sewer, to lead sewage down without splashing
Show answer & solution
Answer: (D) an incoming sewer is much higher than the outgoing sewer, to lead sewage down without splashing
A drop pipe is used when the difference in invert level exceeds about 0.6 m, preventing erosion and splashing.
Question 31
Sewer joints must be made
- permeable, to let sewage soak into the soil
- open, to allow groundwater in and sewage out freely so that pipes never surcharge
- watertight to limit infiltration of groundwater and exfiltration of sewage
- flexible but with no sealing requirement
Show answer & solution
Answer: (C) watertight to limit infiltration of groundwater and exfiltration of sewage
Leaky joints cause infiltration, groundwater and soil pollution, and root intrusion.
Question 32
Settleable solids in sewage are the portion of suspended solids that
- pass through a standard glass-fibre filter
- cannot settle under any conditions and must be removed by chemical coagulation and filtration
- are dissolved and counted as TDS
- settle in a quiescent sample within a short set period, as measured in an Imhoff cone
Show answer & solution
Answer: (D) settle in a quiescent sample within a short set period, as measured in an Imhoff cone
Settleable solids are measured in an Imhoff cone after 1 hour (mL/L) and are removable by plain sedimentation.
Question 33
Cross-connection control in plumbing is intended mainly to
- reduce the sewage flow leaving the building during peak hours
- raise the pressure in the distribution main of the building
- prevent backflow of contaminated water into the potable supply
- allow mixing of potable and non-potable supplies when needed
Show answer & solution
Answer: (C) prevent backflow of contaminated water into the potable supply
Backflow preventers and air gaps protect the potable supply from contamination.
Question 34
Sewers of a combined system are generally larger than those of a separate system because they must carry
- only the dry-weather flow of sanitary sewage, but with a larger safety factor for future growth
- sanitary sewage flow that is much greater than in a separate system because of added infiltration
- a smaller flow than a separate system, which needs a larger pipe area to move it
- the combined peak of sewage and storm runoff, which is far larger than sewage alone
Show answer & solution
Answer: (D) the combined peak of sewage and storm runoff, which is far larger than sewage alone
Design flow = peak sewage + storm runoff; storm runoff usually far exceeds sewage flow.
Question 35
The main function of a trap fitted beneath a plumbing fixture is to
- slow down the wastewater flowing in the branch drain
- hold a water seal that blocks sewer gases from the building
- raise the flow rate of water through the fixture outlet
- treat the wastewater before it reaches the public sewer
Show answer & solution
Answer: (B) hold a water seal that blocks sewer gases from the building
The retained water seal blocks foul gas and small vermin from passing back through the fixture.
Question 36
Which of the following is a commonly used trap in house drainage?
- L-trap
- P-trap
- T-trap
- Z-trap
Show answer & solution
Answer: (B) P-trap
P-trap (and S-trap) have a curved water-retaining bend; the P-trap is most common.
Question 37
The maximum permissible velocity in sewer design is specified mainly to
- ensure the sewer runs full at all times
- prevent erosion and abrasion of the sewer pipe by high-velocity flow
- reduce the minimum gradient needed for self-cleansing
- prevent suspended solids from being carried along with the sewage in the sewer pipe
Show answer & solution
Answer: (B) prevent erosion and abrasion of the sewer pipe by high-velocity flow
Limits (about 2.4-3 m/s depending on material) prevent scour and wear of the invert.
Question 38
Loss of trap seal results in
- an increase in water pressure in the fixture
- backflow of clean water into the supply line
- foul sewer gases entering the building
- blockage of the sewer line
Show answer & solution
Answer: (C) foul sewer gases entering the building
Without the water seal, sewer gases pass into the building, causing odour and health hazards.
Question 39
A house sewer connection generally includes
- a water meter and stop-cock to record and regulate the sewage leaving the house
- a pump and pressure tank fitted to every house to lift the sewage to the street sewer
- a house drain joined to the street sewer, usually with an inspection chamber near the boundary
- a grit chamber and a sedimentation tank installed at each individual house
Show answer & solution
Answer: (C) a house drain joined to the street sewer, usually with an inspection chamber near the boundary
House drains connect through a Y-junction or manhole, with an inspection chamber for access.
Question 40
Sewers are normally designed to flow
- by gravity as open-channel flow, running part full at design peak flow
- upwards under pump pressure along the whole length
- full under pressure like water mains, which keeps the self-cleansing velocity constant
- completely full at all times to prevent air entry
Show answer & solution
Answer: (A) by gravity as open-channel flow, running part full at design peak flow
Sewers are gravity conduits designed to run about 0.5-0.8 full at peak, leaving air space for ventilation.
Question 41
A peak factor is applied to average sewage flow because
- sewage flow varies through the day, with peak-hour flow well above the daily average
- sewage flow is constant through the day and year, so a peak factor is not needed
- peak flow stays equal to the average flow, and the factor only allows for future population growth
- it converts the flow from BOD to COD units for the design of aeration tanks
Show answer & solution
Answer: (A) sewage flow varies through the day, with peak-hour flow well above the daily average
Sewers are designed for peak flow (peak factor ≈ 2 to 3 for small populations, lower for large ones, e.g. Babbit or Harmon).
Question 42
Which statement about sewer appurtenances is correct?
- Only plain pipes are required, since accessories add cost without any technical benefit
- A sewerage system needs manholes, drop manholes, siphons and vents besides the pipes
- Appurtenances are the same as water supply fittings
- Appurtenances are needed only for storm sewers
Show answer & solution
Answer: (B) A sewerage system needs manholes, drop manholes, siphons and vents besides the pipes
Appurtenances provide access, grade change, obstacle crossing, ventilation and flow control.
Question 43
Sewer design (peak) flow generally includes
- peak domestic flow only, with industrial flow and infiltration excluded in all sewer systems
- a fixed per capita flow for all sewers, with no allowance for infiltration or industrial discharge
- average dry-weather flow only, since peaks are absorbed by the pipe's reserve capacity
- peak domestic and industrial flow plus infiltration, and storm water in a combined system
Show answer & solution
Answer: (D) peak domestic and industrial flow plus infiltration, and storm water in a combined system
Design Q = peak sewage + infiltration (+ storm runoff in combined sewers).
Question 44
A sanitary plumbing (house drainage) system is generally designed to
- supply treated water to the fixtures from the municipal main
- remove wastewater from fixtures and keep sewer gas out
- treat wastewater to drinking standard inside the building itself
- store sewage within the building for periodic tanker removal
Show answer & solution
Answer: (B) remove wastewater from fixtures and keep sewer gas out
House drainage conveys wastewater to the sewer with traps and vents preventing entry of sewer gas.
Question 45
Grease and oil in sewage cause problems in sewers mainly by
- increasing the velocity of sewage flow
- dissolving the sewer pipe material
- accumulating on pipe walls with debris and forming blockages and backups
- improving flow by lubricating the pipe walls, which reduces friction and the required gradient
Show answer & solution
Answer: (C) accumulating on pipe walls with debris and forming blockages and backups
Grease congeals in sewers, reducing capacity; grease traps are provided at kitchens and workshops.
Question 46
Sewage is classified by origin into
- raw, settled and final sewage, according to the stage of treatment reached
- domestic (sanitary) sewage, industrial wastewater and, in combined systems, storm water
- surface, ground and rain sewage, according to the water source from which it originates
- primary, secondary and tertiary sewage, classified by the degree of treatment received
Show answer & solution
Answer: (B) domestic (sanitary) sewage, industrial wastewater and, in combined systems, storm water
Classification by source: domestic, industrial and storm water (infiltration also contributes).
Question 47
For the same wastewater sample, COD is generally
- equal to or greater than BOD, since the chemical test oxidizes more substances
- always exactly equal to BOD
- unrelated to BOD in magnitude
- always less than BOD, because the chemical test only attacks the readily degradable fraction
Show answer & solution
Answer: (A) equal to or greater than BOD, since the chemical test oxidizes more substances
COD includes non-biodegradable organics, so COD ≥ ultimate BOD ≥ BOD5.
Question 48
A flushing cistern is used to
- store a fixed quantity of water and release it quickly to flush
- hold sewage before it is discharged to the public sewer
- supply drinking water to the whole building at constant pressure
- treat the wastewater coming from the water closet on site
Show answer & solution
Answer: (A) store a fixed quantity of water and release it quickly to flush
The cistern holds a fixed volume that is discharged quickly to wash the pan clear.
Question 49
Suspended solids in sewage are the
- volatile fraction driven off at 103°C
- fraction that is lost on ignition at 550°C only
- undissolved particulate fraction that can be removed by sedimentation or filtration
- dissolved fraction that passes through a standard glass-fibre filter without being retained
Show answer & solution
Answer: (C) undissolved particulate fraction that can be removed by sedimentation or filtration
SS are retained on a filter (e.g. 1.2 µm); dissolved solids pass through.
Question 50
Sewers are commonly made of
- vitrified clay, concrete (plain or reinforced), and plastic pipes such as PVC or HDPE
- galvanized iron and cast iron only, since plastic pipes cannot withstand sewage
- brass and gunmetal pipes, because they are cheap and available in large diameters
- lead and copper pipes, because they resist the corrosive action of sewage
Show answer & solution
Answer: (A) vitrified clay, concrete (plain or reinforced), and plastic pipes such as PVC or HDPE
Common sewer materials: stoneware/vitrified clay, concrete, RCC, cast/ductile iron, PVC and HDPE.